2021
DOI: 10.1109/access.2021.3066192
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Effect of Motion Path on Leg Muscle Load and Evaluation of Device to Support Leg Motion During Robot Operation by Reducing Muscle Load

Abstract: Because the human arm and leg have a similar skeletal structure, it may be possible to use the leg to operate a robot by the master-slave method. However, operation by the leg with six degrees of freedom has two problems. First, people move their ankle with a curved motion despite intending to move it linearly. Second, it is a burden for the operator to suspend their legs in the air during operation. This study dealt with these problems. For the first problem, we hypothesized that one of the reasons was that t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
1
1

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 30 publications
(26 reference statements)
0
2
0
Order By: Relevance
“…The operability of the device was significantly improved when the appropriate operating method was applied (Komori et al, 2018b). Isotonic devices can be used to accurately operate the position of the target object (Komori, 2018b(Komori, , 2019(Komori, , 2020bKato et al, 2021). However, applying the isotonic method to the lower limbs requires keeping the lower limbs constantly suspended in the air to enable multiple DOF movements (Kato et al, 2021).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The operability of the device was significantly improved when the appropriate operating method was applied (Komori et al, 2018b). Isotonic devices can be used to accurately operate the position of the target object (Komori, 2018b(Komori, , 2019(Komori, , 2020bKato et al, 2021). However, applying the isotonic method to the lower limbs requires keeping the lower limbs constantly suspended in the air to enable multiple DOF movements (Kato et al, 2021).…”
Section: Introductionmentioning
confidence: 99%
“…Isotonic devices can be used to accurately operate the position of the target object (Komori, 2018b(Komori, , 2019(Komori, , 2020bKato et al, 2021). However, applying the isotonic method to the lower limbs requires keeping the lower limbs constantly suspended in the air to enable multiple DOF movements (Kato et al, 2021). Such a situation is rare in daily life and can be burdensome for the lower limbs.…”
Section: Introductionmentioning
confidence: 99%