2020
DOI: 10.1002/mp.14369
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of dosimetric impact of intrafraction translation and rotation during respiratory‐gated stereotactic body radiotherapy with real‐time tumor monitoring of the lung using a novel six degrees‐of‐freedom robotic moving phantom

Abstract: This study aimed to develop a six degrees-of-freedom (6DoF) robotic moving phantom for evaluating the dosimetric impact of intrafraction rotation during respiratory-gated radiotherapy with real-time tumor monitoring in the lung. Materials and Methods: Fifteen patients who had undergone respiratory-gated stereotactic body radiotherapy (SBRT) with the SyncTraX system for lung tumors were enrolled in this study. A waterequivalent phantom (WEP) was set at the tip of the robotic arm. A log file that recorded the th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
10
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(11 citation statements)
references
References 31 publications
1
10
0
Order By: Relevance
“…Several methods have been proposed to evaluate the dosimetric impact of delivery errors. [1][2][3][4][5][6][7][8] Lujan et al 1 proposed a convolution method to estimate the dose delivered to liver lesions subject to intrafractional motion. They convolved planned dose with an organ motion probability distribution function, based on a simple mathematical breathing model, expressed as a function of position rather than a function of time.…”
Section: Introductionmentioning
confidence: 99%
See 4 more Smart Citations
“…Several methods have been proposed to evaluate the dosimetric impact of delivery errors. [1][2][3][4][5][6][7][8] Lujan et al 1 proposed a convolution method to estimate the dose delivered to liver lesions subject to intrafractional motion. They convolved planned dose with an organ motion probability distribution function, based on a simple mathematical breathing model, expressed as a function of position rather than a function of time.…”
Section: Introductionmentioning
confidence: 99%
“…To our knowledge, few studies have quantified the dosimetric effects of target rotations for stereotactic body radiation therapy (SBRT) liver treatments . 4, 5 Shiinoki et al 7 assessed the dosimetric impact of errors in respiratory gated beam delivery with real time motion monitoring of implanted fiducials for lung tumors. They used a high precision robotic arm to translate and rotate the phantom based on the observed motions of patients during conventional gantry mounted linac beam delivery.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations