2006
DOI: 10.1007/s00216-006-0906-3
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of domperidone in pharmaceutical formulations and wastewater by differential pulse voltammetry at a glassy-carbon electrode

Abstract: The redox characteristics of the drug domperidone at a glassy-carbon electrode (GCE) in aqueous media were critically investigated by differential-pulse voltammetry (DPV) and cyclic voltammetry (CV). In Britton-Robinson (BR) buffer of pH 2.6-10.3, an irreversible and diffusion-controlled oxidation wave was developed. The dependence of the CV response of the developed anodic peak on the sweep rate (nu) and on depolizer concentration was typical of an electrode-coupled chemical reaction mechanism (EC) in which a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2009
2009
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 25 publications
(11 citation statements)
references
References 23 publications
0
11
0
Order By: Relevance
“…Of the non-chromatographic methods, the methods based on voltammetric [4,5] and potentiometric sensor [6] techniques involve rigid pH control. Compared with most of the existing methods for DOM, the present methods are very simple and cost effective.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Of the non-chromatographic methods, the methods based on voltammetric [4,5] and potentiometric sensor [6] techniques involve rigid pH control. Compared with most of the existing methods for DOM, the present methods are very simple and cost effective.…”
Section: Discussionmentioning
confidence: 99%
“…Several methods have been reported for the determination of domperidone in pharmaceuticals, including differential pulse voltammetry [4], anodic difference pulse voltammetry [5], potentiometry [6], planar chromatography [7], high-performance liquid chromatography [8][9][10][11][12][13][14][15][16][17][18][19] and high-performance thin-layer chromatography [20][21][22][23][24][25]. Many of these techniques are deficient in simplicity, cost-effectiveness and easy accessibility.…”
mentioning
confidence: 99%
“…Among various contaminants, the presence of drugs and pharmaceuticals in the water and wastewater is alarming and dangerous as some of them can disturb enzymatic, hormonal and genetic systems of human beings. Many drug residues have been found in water [23,24]. In the present study a voltammetric method has been developed for the analysis of nitrofurantoin.…”
Section: Nitrofurantoinmentioning
confidence: 99%
“…Planar chromatography, 4 high-performance liquid chromatography [5][6][7][8][9][10][11][12][13][14][15] and highperformance thin-layer chromatography [16][17][18][19][20] have been used to assay DOM. The drug has also been assayed by differential pulse voltammetry 21 and anodic difference pulse voltammetry 22 at a glassy carbon electrode in Britton-Robinson buffer. Application of potentiometric sensors 23 for the analysis of DOMcontaining tablets using PVC membrane and carbon paste sensors has also been reported.…”
Section: Standard Dom Solutionmentioning
confidence: 99%