2015
DOI: 10.2319/102513-780.1
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Class II patients, successfully treated with the straight-wire and Forsus appliances, based on cervical vertebral maturation status

Abstract: Following an initial worsening of the Class II molar relationship as a result of straight-wire appliance effects, Forsus appliance treatment initiated during cervical vertebral maturation status (CS) 3-4 elicits more effective and efficient correction of Class II molar relationships than when initiated during CS 5-6. Data support that these effects are due mainly to maxillary skeletal and dentoalveolar restraint during a period of more rapid mandibular growth.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

3
14
0
2

Year Published

2015
2015
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 17 publications
(20 citation statements)
references
References 13 publications
3
14
0
2
Order By: Relevance
“…Based on this and supported by the literature, it was possible to consider and suggest some treatment options to the patient, such as a surgical-orthodontic treatment [20,38]; upper first molar extractions [39,40], the use of intermaxillary Class II elastics [24,41], which would need patient cooperation; and the use of fixed functional appliances-rigid [18,19,[21][22][23]25], semi-rigid [8,11,12,37], but, mainly, hybrid appliances as the Forsus™ Fatigue Resistant Device [3,7,11,[13][14][15]17,[32][33][34]35]. The chosen protocol was to use the Forsus™ Fatigue Resistant Device that has shown to be an effective device, providing greater comfort to patients [7,11,[14][15][16][17]33,34] and good resistance [10,13,15,35] when treating Class II malocclusions.…”
Section: Treatment Optionsmentioning
confidence: 99%
See 4 more Smart Citations
“…Based on this and supported by the literature, it was possible to consider and suggest some treatment options to the patient, such as a surgical-orthodontic treatment [20,38]; upper first molar extractions [39,40], the use of intermaxillary Class II elastics [24,41], which would need patient cooperation; and the use of fixed functional appliances-rigid [18,19,[21][22][23]25], semi-rigid [8,11,12,37], but, mainly, hybrid appliances as the Forsus™ Fatigue Resistant Device [3,7,11,[13][14][15]17,[32][33][34]35]. The chosen protocol was to use the Forsus™ Fatigue Resistant Device that has shown to be an effective device, providing greater comfort to patients [7,11,[14][15][16][17]33,34] and good resistance [10,13,15,35] when treating Class II malocclusions.…”
Section: Treatment Optionsmentioning
confidence: 99%
“…It is a comfortable device [7], as it does not completely limit the mandible movement and, in the current version, it shows a very low breakage rate [10,14,[32][33][34]. The Forsus appliance, when installed in the upper first molar tube in the lower leveling arch wire, at the distal of the cuspid bracket [3,11,15,17] or, at the distal of the lower first premolar [14], exerts a force of 220 g approximately in both jaws, in opposite directions [15,35]. And, the time it takes to completely correct a Class II malocclusion may vary from 5 -8 months on average [6,14,15,17].…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations