Analysis of cement by inductively coupled plasma optical emission spectrometry using slurry nebulization

Abstract: An investigation was conducted to determine the feasibility of analysing cement by introducing it as a slurry into an inductively coupled plasma optical emission spectrometer (ICP-OES). A complete analysis of cement for major (Ca, Si, Mg, Al, Fe) and minor and trace elements (S, K, Ti, Na, P, Mn and Sr) was accomplished. Calibration was performed either by using reference materials as slurries or by using simple aqueous standards. A combination of hydrochloric acid (1% v/v), glycerol (0.01% m/v) and agitation … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
20
0

Year Published

2004
2004
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 29 publications
(21 citation statements)
references
References 7 publications
0
20
0
Order By: Relevance
“…Additionally, residence times could also be altered. Some publications proposed the use of increasing masses of certified reference materials for the calibration, [25][26][27] but aqueous solutions could also be used. 27,[31][32][33] The use of the generalized standard additions method (GSAM), an expansion of the conventional standard additions method, has also been proposed for slurry analysis in a dual view 28 and in an axially viewed ICP OES.…”
Section: Use Of Icp Oes With Axially Viewed Configuration For Analysimentioning
confidence: 99%
See 1 more Smart Citation
“…Additionally, residence times could also be altered. Some publications proposed the use of increasing masses of certified reference materials for the calibration, [25][26][27] but aqueous solutions could also be used. 27,[31][32][33] The use of the generalized standard additions method (GSAM), an expansion of the conventional standard additions method, has also been proposed for slurry analysis in a dual view 28 and in an axially viewed ICP OES.…”
Section: Use Of Icp Oes With Axially Viewed Configuration For Analysimentioning
confidence: 99%
“…Spectral interferences related to the high amount of matrix constituents, solid particle deposition in the optical interface and EIE's interferences did not affect severely slurry analysis. When compared to techniques such as Xray fluorescence (XRF) for cement analysis, the use of ICP OES presented some advantages, such as lower matrix-interference effects, better sensitivity, linearity of calibration curves over several orders of magnitude, excellent reproducibility, great versatility and the possibility of analyzing non-metallic elements, such as C, B, P, and S. 25 Generally, grinding steps have to be adopted in analytical routine for the analysis of slurry samples. The ideal particle size to be introduced in ICP OES is an important parameter.…”
Section: Use Of Icp Oes With Axially Viewed Configuration For Analysimentioning
confidence: 99%
“…Inductively coupled plasma optical emission spectrometry (ICP OES) is a powerful multi-elemental technique applied to chemical analysis 1 which requires a sample preparation step involving only a simple dilution or total dissolution if the sample is a solid. 1,2 Concerning solid samples, methodologies involving suspensions prepared from finely powdered samples (slurries) have become acceptable 1,3,4 as well as the application of extraction methods 5 depending the nature of sample. ICP OES presents some advantages such as low degree of matrix-interference, high analytical frequency, linearity of calibration curves over several orders of magnitude and excellent reproducibility.…”
Section: Introductionmentioning
confidence: 99%
“…Standard reference materials [4,5], internal standards [6], intrinsic internal standards [7], as well as empirical correction factors [8] have all been successfully applied to compensate for different transportation and excitation properties. There are, however, certain limitations to their application.…”
Section: Introductionmentioning
confidence: 99%