Analysis of biomolecules using electrospray and nanoparticle methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
64
0

Year Published

2000
2000
2018
2018

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 83 publications
(64 citation statements)
references
References 55 publications
0
64
0
Order By: Relevance
“…Charge reduction of the sprayed droplets to unity is essential for the sizing method. 15 In an electrical-mobility detection technique (DMA), the aerosol passes through a bipolar ion neutralizer, which generates a high level of positive and negative ions. The neutralizer brings the aerosol charge level to a Fuch's equilibrium charge distribution.…”
Section: Methodsmentioning
confidence: 99%
“…Charge reduction of the sprayed droplets to unity is essential for the sizing method. 15 In an electrical-mobility detection technique (DMA), the aerosol passes through a bipolar ion neutralizer, which generates a high level of positive and negative ions. The neutralizer brings the aerosol charge level to a Fuch's equilibrium charge distribution.…”
Section: Methodsmentioning
confidence: 99%
“…interrogation of whole proteins on proteome scale in the gas-phase, also demand accurate mass calibration of mass spectrometer at high m/z values. In addition to the examples discussed above, alternative approaches such as nanoelectromechanical mass spectrometry [110], on a gas-phase electrophoretic mobility molecular analyzer (GEMMA) [111] have been used to record the mass of particles up to 100 MDa (for a recent review see [112]). …”
Section: Mass Calibration At High Mass-to-charge Ratiosmentioning
confidence: 99%
“…As previously described by Kaufman in detail [3], nES GEMMA separates analytes according to their electrophoretic mobility diameter (EMD) in the gas phase, which can directly be correlated to the dry particle diameters in the nm range. Consequently, the molecular weights can be calculated by application of a correlation derived from respective standard compounds [3, 4].…”
Section: Introductionmentioning
confidence: 99%
“…Consequently, the molecular weights can be calculated by application of a correlation derived from respective standard compounds [3, 4]. In brief, multiply charged droplets produced in cone jet mode in the nES unit are dried and simultaneously charge-reduced in a bipolar atmosphere (induced by a 210 Po source) and subsequently introduced into the nano differential mobility analyzer (nDMA).…”