Analysis of Beta Attenuation Monitor Filter Rolls for Particulate Matter Speciation

Abstract: Instruments such as Beta Attenuation Monitors (BAMs) provide real-time PM 2.5 mass concentration data and are now widely used in compliance monitoring networks. These devices collect the PM on a filter tape in 1-hour samples. In this work, the use of BAM filter spots for chemical speciation was investigated. Filter tapes from several sites in California were analyzed for a series of chemical species including elements, ions, organic and elemental carbon, and molecular markers. A major issue was the blank value… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(15 citation statements)
references
References 6 publications
0
15
0
Order By: Relevance
“…Based on blank spot analyses, it was determined that measurement of organic and elemental carbon (OC/EC) and elements were infeasible. [18] The TEOM method ( Figure 6b) uses a cone-shaped elemental oscillation microbalance. Similar to GMM and BAM, TEOM also uses a filter to collect PM samples, but the detection principle is different.…”
Section: 2laser Based Optical Methodsmentioning
confidence: 99%
“…Based on blank spot analyses, it was determined that measurement of organic and elemental carbon (OC/EC) and elements were infeasible. [18] The TEOM method ( Figure 6b) uses a cone-shaped elemental oscillation microbalance. Similar to GMM and BAM, TEOM also uses a filter to collect PM samples, but the detection principle is different.…”
Section: 2laser Based Optical Methodsmentioning
confidence: 99%
“…The 24 h concentrations of PM2.5 and PM10 inside both chambers were measured using an ambient continuous monitor (HT9600, Guangdong, China). The concentration of the outside environment was determined by Beta Attenuation Monitors (Raja et al, 2017) using MetOne 1020 BAMs (The Met One Instruments, Inc. model BAM-1020). Concentrations of CO (8-h mean) was determined by a non-dispersive infrared method.…”
Section: Methodsmentioning
confidence: 99%
“…Researchers based in the US 19 investigated whether it was possible to recover and analyse filter spots to provide additional time-resolved chemical data. The glass-fibre filter tapes currently used contain elemental impurities which limit the successful determination of many metals of potential interest.…”
Section: Sampling Techniquesmentioning
confidence: 99%