2018
DOI: 10.12659/msm.907390
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Base Monomer Elution from 3 Flowable Bulk-Fill Composite Resins Using High Performance Liquid Chromatography (HPLC)

Abstract: BackgroundThe aim of this study was to evaluate the elution of BisGMA, UDMA, TEGDMA, and HEMA monomers from flowable bulk fill composite resins with different resin matrix compositions, polymerized in 4-mm-thick layers, into 3 elution media.Material/MethodsThree bulk-fill (SDR® (SDR), X-tra base (XB) and BEAUTIFIL-Bulk Flowable (BF)) resin-composites were tested. Cylindrical samples were immersed in 100% ethanol, 75% ethanol, and distilled water. The concentrations of the monomers were measured using the HLPC … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

9
34
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 29 publications
(46 citation statements)
references
References 52 publications
9
34
1
Order By: Relevance
“…As another considerable finding, the present study showed that, various resin composites released different amount and types of monomers. According to this result, the second hypothesis was rejected, and this result was consistent with the results of other studies ( 19 - 21 ). Lempel et al reported different amounts of released monomers from bulk-fill resin composites ( 19 ).…”
Section: Discussionsupporting
confidence: 92%
See 2 more Smart Citations
“…As another considerable finding, the present study showed that, various resin composites released different amount and types of monomers. According to this result, the second hypothesis was rejected, and this result was consistent with the results of other studies ( 19 - 21 ). Lempel et al reported different amounts of released monomers from bulk-fill resin composites ( 19 ).…”
Section: Discussionsupporting
confidence: 92%
“…Additionally, according to the manufacturer information, Bis-GMA does not exist in XB composite structure, also the results of this study confirmed that, this monomer was not released from XB composite. Łagocka et al in a study investigated the amount of monomer release from bulk-fill resin composites, and they showed that, any of the studied monomers such as Bis-GMA was not released from XB composite ( 21 ). Bis-GMA molecule is a monomer with high molecular weight, high capacity of hydrogen band and low molecular movement ( 26 ).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…ScF, and to a lesser extent XB and EXP, was less affected by solvents; however, some bulk-fills, particularly low-viscosity flowables such as VBF, FBF, and SDRF, were more susceptible to solvent attack, as indicated by a recent study reporting that XB released no monomers after storage in water or absolute ethanol [7]. The persistence of high flexural properties of ScF in solvents may be attributable to the presence of multivariant filler particles sizes, together with relatively high filler content that shortens filler spacing, thus delaying diffusion of plasticizing solvents [34].…”
Section: Discussionmentioning
confidence: 98%
“…In addition to these combined forces during mastication, solvent uptake can gradually damage restorations, as it is associated with subsurface cracking that may shorten its lifespan [6,7]. A previous study reported that a composite material with a low modulus of elasticity when placed in stress-bearing areas suffered greater distortion and marginal deterioration under masticatory forces [8].…”
Section: Introductionmentioning
confidence: 99%