2001
DOI: 10.1016/s0020-7403(00)00090-4
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of acousto-ultrasonic characteristics for contact-type transducers coupled to composite laminated plates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2002
2002
2021
2021

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 14 publications
0
5
0
Order By: Relevance
“…Moreover, the contact transducers can be easily designed, configured or adjusted depending on the type of defects or damages and the availability of access region of the structure. Thus, the contact transducers are widely used in the various field of NDT such as the detection of flaws with straight beam test, inspection of delamination or disbonds in composites and many thickness gauging applications [ 10 , 11 , 12 , 13 ]. In this research work, the focus was kept on the contact-type ultrasonic transducers for the generation of GWs.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, the contact transducers can be easily designed, configured or adjusted depending on the type of defects or damages and the availability of access region of the structure. Thus, the contact transducers are widely used in the various field of NDT such as the detection of flaws with straight beam test, inspection of delamination or disbonds in composites and many thickness gauging applications [ 10 , 11 , 12 , 13 ]. In this research work, the focus was kept on the contact-type ultrasonic transducers for the generation of GWs.…”
Section: Introductionmentioning
confidence: 99%
“…In AU procedure, the response of normal contact pressure sensed by the receiving transducer is obtained. Based on statistical analysis, numerical results are carried out to investigate influence of various parameters including simulating frequency, transducer modes, transducers location et al [7].…”
Section: Factors Influencing Swf Measurementmentioning
confidence: 99%
“…2 given as follows. As to transducers location optimal problem, several literatures [7,11] have reported. (…”
Section: Factors Influencing Swf Measurementmentioning
confidence: 99%
“…Many researchers experimentally reported the defect estimation of composite structures based on the UGW interaction [ 7 , 14 , 15 ]. Moreover, many studies have been conducted to understand the dispersive and multimodal behaviour of UGWs [ 16 , 17 , 18 , 19 , 20 ].…”
Section: Introductionmentioning
confidence: 99%