In this paper we approach twin‐T design with a view to controlling the sensitivity of the transmission zero with respect to component variations, according to criteria that are of particular interest in the design of hybrid integrated linear active networks. We give design examples and derive conditions that relate null depth and component characteristics with expected zero displacement in the s‐plane.