2014
DOI: 10.1016/j.measurement.2014.03.003
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of a national comparison in the field of electrical low dc resistance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 9 publications
0
9
0
Order By: Relevance
“…Normally, when in an ILC are involved an NMI and calibration Laboratories belonging to the same country, it is important to correctly evaluate the possible correlation between the measurements of the NMI and the secondary Laboratories as normally the Laboratories send their reference standards to the NMI for calibration. Suggestion for this evaluation can be found in [1,[5][6][7]10]. The ILC results are reported in Tables 1-3 Table 3.…”
Section: Analysis Of the Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Normally, when in an ILC are involved an NMI and calibration Laboratories belonging to the same country, it is important to correctly evaluate the possible correlation between the measurements of the NMI and the secondary Laboratories as normally the Laboratories send their reference standards to the NMI for calibration. Suggestion for this evaluation can be found in [1,[5][6][7]10]. The ILC results are reported in Tables 1-3 Table 3.…”
Section: Analysis Of the Resultsmentioning
confidence: 99%
“…Another kind of ILCs involves a NMI and secondary Laboratories of the same country accredited or not, so belonging to the same measurement system. The ILC reference values of these comparisons are the measurement values given by the NMI that is normally at an upper metrological level with respect the other Laboratories [5][6][7][8]. In this paper an ILC, made according to the EN ISO/IEC 17043 international Standard [9] between the National Institute of Metrological Research (INRIM) and the European space research and technology Centre (ESA-ESTEC) on DC Voltage, DC Resistance and Electrical Capacitance is presented.…”
Section: Introductionmentioning
confidence: 99%
“…This system allows checking the compatibility around all the world. Secondary laboratories accredited by national accreditation services signatory of the EA MLA 3 , besides to participate to ILCs with their NMIs or ILCs providers, can participate also to international ILCs organized by the EA 4 .…”
Section: Reports Of the Ilcsmentioning
confidence: 99%
“…Because of increasing demand for high accuracy for industry and for the scientific metrology, more accurate measurement methods are being developed. There are different methods for measuring lowohmic resistance standards such as direct current comparator with range extender, direct reading with a digital multimeter (DMM), and substitution method [3]. There are also volt-ampere-metric and ratio technique methods.…”
Section: Introductionmentioning
confidence: 99%