2017 IEEE 8th International Symposium on Power Electronics for Distributed Generation Systems (PEDG) 2017
DOI: 10.1109/pedg.2017.7972462
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of a grid-forming converter based on repetitive control in centralized AC microgrid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
2
0
2

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 25 publications
0
2
0
2
Order By: Relevance
“…Various topologies of the shunt‐connected static distribution compensator (DSTATCOM) for power quality enhancement have been suggested by the researchers, that is, single‐phase, three‐phase three‐wire, and three‐phase four‐wire strategies 5,6 . In Maurya et al 7 and Huang et al, 8 a single‐phase DSTATCOM topology is presented for the residential system, whereas in Naqvi and Singh 4 and Singh et al, 5 the three‐phase three‐wire and three‐phase four‐wire topologies are presented.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Various topologies of the shunt‐connected static distribution compensator (DSTATCOM) for power quality enhancement have been suggested by the researchers, that is, single‐phase, three‐phase three‐wire, and three‐phase four‐wire strategies 5,6 . In Maurya et al 7 and Huang et al, 8 a single‐phase DSTATCOM topology is presented for the residential system, whereas in Naqvi and Singh 4 and Singh et al, 5 the three‐phase three‐wire and three‐phase four‐wire topologies are presented.…”
Section: Introductionmentioning
confidence: 99%
“…Adaptive neural network (ADALINE) control offers a better training procedure but suffers from the linear separability constraint of the perceptron. However, the hardware implementation of ADALINE requires a microcontroller with parallel processing 5–26 …”
Section: Introductionmentioning
confidence: 99%
“…Li et al, 2021;Rocabert et al, 2012). O controle formador de rede, também é conhecido na literatura como controle V-f e é utilizado principalmente em sistemas UPS e microrredes ilhadas, pois nestes casos a frequência e a amplitude da tensão devem ser controlados de forma autônoma, ou seja, sem suporte da rede elétrica (Antunes et al, 2017;Lliuyacc et al, 2017;Rajesh et al, 2017;Zhang, C. et al, 2016). Deve ser destacado que neste tipo de controle existe a necessidade de controlar a potência fornecida à microrrede para manter o balanço carga-geração.…”
Section: Controle Local Dos Inversoresunclassified
“…Como consequência, a segunda estratégia consiste na GD suprir simultaneamente potência ativa e a parcela de correntes não lineares das cargas locais, a fim de fornecer/drenar unicamente correntes puramente senoidais. Neste caso o inversor seria controlado a operar tanto como FAPP, bem como sistema de GD, similar aos conversores multifuncionais estudados em (Brandão, Marafão, Paredes, et al, 2013;Busarello et al, 2018;Campanhol et al, 2017 (Gothner et al, 2019;Lorzadeh et al, 2017;Micallef et al, 2017;Peng, Shuai, Liu, et al, 2020;Sreekumar e Khadkikar, 2016, 2017.…”
Section: Definições Conceitos Gerais E Regulamentação Nacionalunclassified