Analysis model development and specification proposal of 154 kV SFCL for the application to a live grid in South Korea

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
10
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(10 citation statements)
references
References 2 publications
0
10
0
Order By: Relevance
“…Recently, a number of practical superconducting fault current limiter (SFCL) devices have been successfully developed and demonstrated by in-grid tests. The current motivation on the applied superconductivity technology to build SFCL devices has been moving from the 10-kV distribution level [26,27] to the 100-kV transmission level [27,28].So far, fault current limiters have been comprehensively studied and applied in AC power grids to limit fault currents and to improve the dynamic performance of the system. However, the application of FCLs in VSC-HVDC systems has not been fully investigated [29].…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Recently, a number of practical superconducting fault current limiter (SFCL) devices have been successfully developed and demonstrated by in-grid tests. The current motivation on the applied superconductivity technology to build SFCL devices has been moving from the 10-kV distribution level [26,27] to the 100-kV transmission level [27,28].So far, fault current limiters have been comprehensively studied and applied in AC power grids to limit fault currents and to improve the dynamic performance of the system. However, the application of FCLs in VSC-HVDC systems has not been fully investigated [29].…”
mentioning
confidence: 99%
“…Recently, a number of practical superconducting fault current limiter (SFCL) devices have been successfully developed and demonstrated by in-grid tests. The current motivation on the applied superconductivity technology to build SFCL devices has been moving from the 10-kV distribution level [26,27] to the 100-kV transmission level [27,28].…”
mentioning
confidence: 99%
“…As seen in Figure 17, without SFCL, all the sag events dropped below and voltage swell dropped above the ITIC curve. However, with the insertion of SFCL, the sag events that can be improved and overvoltage are lessened, which dropped into the acceptable power the curve of ITIC are at B2, 3,4,15,16,17. Figure 18 represents the voltage sag and overvoltage from B2 to B17 when a short circuit occurred at tie breaker.…”
Section: B Case 2: the Fault Occurred At Tie Breaker Of Feeder 1 Witmentioning
confidence: 99%
“…SFCL offer an excellent solution for the increased level of short circuits in power systems, which can improve the stability of the power system. And various types of SFCLs are implemented at substation of power distribution system in real world power grids of many countries [1][2][3][4][5][6].…”
Section: Introductionmentioning
confidence: 99%
“…Several kinds of HTS electric power devices such as HTS cable and HTS-FCL are in progress of field test after R&D phase [1][2][3]. Such devices require a reliable and efficient high-capacity cryocooler and a crank-driven type Stirling cryocooler is widely used at present.…”
Section: Introductionmentioning
confidence: 99%