Analysis Methodology for Differential Mode Interference in Energy Supply System of Hybrid DC Breaker

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 16 publications
(9 citation statements)
references
References 16 publications
0
9
0
Order By: Relevance
“…When the capacitor voltage exceeds the MOV action voltage, the fault current will transfer to the energy absorber branch. The current change rate of stage VI will reach kA/ms level, which is also called the second current transfer process, and its current can be expressed by Equation ( 13)- (15).…”
Section: Mechanism and Characterisation Of Current Generationmentioning
confidence: 99%
See 1 more Smart Citation
“…When the capacitor voltage exceeds the MOV action voltage, the fault current will transfer to the energy absorber branch. The current change rate of stage VI will reach kA/ms level, which is also called the second current transfer process, and its current can be expressed by Equation ( 13)- (15).…”
Section: Mechanism and Characterisation Of Current Generationmentioning
confidence: 99%
“…For DC circuit breaker, the problems in electromagnetic transient process and electrical stress are mainly concerned [13,14]. X. Cui and others analysed the mechanism of differential mode interference in the HCB power supply system, established the broadband equivalent circuit model of the power supply system, and proposed the suppression measures [15]. Because of the short operation time of HCB, there is no literature on the transient MF disturbance at the DCU, and there is no measurement data of the internal magnetic field.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, the primary and secondary equipment in the high-voltage DCCB is highly integrated [9,10], and the CMD can easily transform into sensitive ports' interference of DCCB through capacitive and inductive coupling or radiation [11], as shown in Figure 1. These differential-mode interferences may cause misjudgement of DCCB protection.…”
Section: Introductionmentioning
confidence: 99%
“…The research and implementation of the former have been relatively mature, while the latter remains an open problem. How to solve the problem of identification of unknown protocols has been an important difficulty in the field of network security [10][11][12].…”
Section: Introductionmentioning