2002
DOI: 10.1016/s0003-2670(01)01561-6
|View full text |Cite
|
Sign up to set email alerts
|

Analysis for Cd, Cu, Ni, Zn, and Mn in estuarine water by inductively coupled plasma mass spectrometry coupled with an automated flow injection system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
37
0

Year Published

2002
2002
2016
2016

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 77 publications
(43 citation statements)
references
References 12 publications
4
37
0
Order By: Relevance
“…The method was then used to analyze acidified (pH 1.7) samples from the California coast. The results were compared to those obtained for the same suite of samples analyzed by a FI system coupled to inductively coupled plasma sector field mass spectrometry (ICP-SFMS) detection (Beck et al 2002). Recently, the method was further optimized to include NTA as an activator, and the periodate salt was changed from potassium periodate (KIO 4 ) to NaIO 4 owing to the higher solubility at neutral pH of the latter (see Resing and Mottl [1992] for the preparation of KIO 4 ).…”
Section: Assessmentmentioning
confidence: 99%
See 2 more Smart Citations
“…The method was then used to analyze acidified (pH 1.7) samples from the California coast. The results were compared to those obtained for the same suite of samples analyzed by a FI system coupled to inductively coupled plasma sector field mass spectrometry (ICP-SFMS) detection (Beck et al 2002). Recently, the method was further optimized to include NTA as an activator, and the periodate salt was changed from potassium periodate (KIO 4 ) to NaIO 4 owing to the higher solubility at neutral pH of the latter (see Resing and Mottl [1992] for the preparation of KIO 4 ).…”
Section: Assessmentmentioning
confidence: 99%
“…Column loading pH-Toyopearl AF-Chelate-650M has been successfully used to quantitatively preconcentrate manganese from seawater at pH 8.8 and 9.0 (Warnken et al 2000;Beck et al 2002). To confirm and establish the optimal pH at which the IDA groups of the resin bind Mn(II), a series of acidified (pH < 1.7) seawater samples with dissolved manganese concentrations ([Mn 2+ ]) of ~ 10 nM were used.…”
Section: Assessmentmentioning
confidence: 99%
See 1 more Smart Citation
“…A column filled with a chelating resin followed by a rinse of matrix elements from the resin and elution of the metals allows one-step concentration and simplification of the matrix (Beck et al ., 2002;Evans et al ., 2005). Pre-concentration and elution can either be made 'off-line' with subsequent analysis of the collected eluate (Ferrarello et al ., 2002) or 'on-line' as part of the (ICP-MS) workflow (Beck et al ., 2002). Using the on-line method gives an elution profile (concentrations versus time) of the metals and the average peak or integrated intensity or the maximum peak intensity is used as being proportional to the sample metal concentration.…”
Section: Pre-concentration Methods For Seawater Analysismentioning
confidence: 99%
“…There are several methods for the determination of zinc such as anodic stripping voltammetry, 1 spectrophotometry, 2 AAS, 3 FAAS, 4 GFAAS, 5 and ICP-MS. 6 These methods are of high sensitivity and accuracy. But some are expensive, timeconsuming, troublesome, and others are toxic.…”
Section: Introductionmentioning