2014
DOI: 10.1109/tpel.2013.2289939
|View full text |Cite
|
Sign up to set email alerts
|

Analysis and Suppression of Leakage Current in Cascaded-Multilevel-Inverter-Based PV Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
53
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 131 publications
(54 citation statements)
references
References 34 publications
1
53
0
Order By: Relevance
“…Referring to the modeling methods and equivalent circuits in [13,22,23], a simplified three-phase equivalent circuit for the high-voltage side of the EPT illustrated in Figure 1b is exhibited in Figure 4. Note that the grid is converted equivalently to a star-connected voltage source for the analysis and calculation of CMV.…”
Section: The CMV At Neutral Pointmentioning
confidence: 99%
See 1 more Smart Citation
“…Referring to the modeling methods and equivalent circuits in [13,22,23], a simplified three-phase equivalent circuit for the high-voltage side of the EPT illustrated in Figure 1b is exhibited in Figure 4. Note that the grid is converted equivalently to a star-connected voltage source for the analysis and calculation of CMV.…”
Section: The CMV At Neutral Pointmentioning
confidence: 99%
“…The literature [13] analyses systematically the CMV in the MV-ASD and establishes a common mode equivalent circuit, then suppresses the CMV by means of an improved modulation scheme. In the literature [22], the characteristics and paths of common mode current (CMI) in cascaded-multilevel-inverter-based photovoltaic system are analyzed, and suppression filters are designed. As for EPTs, related analysis of the CMV in the previously mentioned literature cannot be applied to them directly, due to their different topologies and control strategies.…”
mentioning
confidence: 99%
“…Several multi-level inverter topologies designed for PV systems with reduction in leakage current and increase in number of the output-voltage levels have been proposed [4,5,6,7]. A modified H-bridge inverter in Fig.…”
Section: Introductionmentioning
confidence: 99%
“…However, few papers have been reported regarding eliminating the leakage current for the singlephase cascaded multilevel inverters. A significant contribution by Zhou and Li is the filter-based leakage current suppression solution for the single-phase cascaded multilevel PV inverter [12]. But the topology-based solution is rarely discussed in literature, and needs further investigation.…”
Section: Introductionmentioning
confidence: 99%