2015
DOI: 10.1016/j.jece.2015.05.002
|View full text |Cite
|
Sign up to set email alerts
|

Analysis and modeling of fixed bed sorption of cesium by AMP-PAN

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
6
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(8 citation statements)
references
References 36 publications
2
6
0
Order By: Relevance
“…This level of irradiation thus has little or no effect on the ion exchange properties of both AMP and AMP-PAN. K d values for Cs + at both concentrations tested remained above 10,000 after 24 h. Under the conditions we tested, both AMP and AMP-PAN follow pseudo-second-order absorption kinetics adhering to the Langmuir isotherm, mirroring previous results [20,30,36]. We have thus demonstrated the efficacy of AMP-PAN as a Cs ion exchange composite under the Cs + concentrations and acidity of spent fuel dissolver conditions following exposure to significant levels of gamma radiation.…”
Section: Discussionsupporting
confidence: 88%
See 3 more Smart Citations
“…This level of irradiation thus has little or no effect on the ion exchange properties of both AMP and AMP-PAN. K d values for Cs + at both concentrations tested remained above 10,000 after 24 h. Under the conditions we tested, both AMP and AMP-PAN follow pseudo-second-order absorption kinetics adhering to the Langmuir isotherm, mirroring previous results [20,30,36]. We have thus demonstrated the efficacy of AMP-PAN as a Cs ion exchange composite under the Cs + concentrations and acidity of spent fuel dissolver conditions following exposure to significant levels of gamma radiation.…”
Section: Discussionsupporting
confidence: 88%
“…The isothermal parameters and regression coefficients calculated from this data and the equivalent Freundlich isotherm interpretation [29] are presented in Table 1. As the data presented in Figure 4 demonstrate, the observed uptake of Cs + by AMP and AMP-PAN fits the pseudo-second-order Langmuir isotherm with a high regression coefficient (R 2 ), mirroring the previous work of Mahendra, Herbst, and Ding [20,30,35]. While the regression coefficients (R 2 ) for the Freundlich isotherm are close to 1, slopes of the lines produced by this method were negative, indicating a poor fit to the technique.…”
Section: Ion Exchange Performancesupporting
confidence: 84%
See 2 more Smart Citations
“…Some of these, including the radioisotopes of Cs ( 134 Cs-t 1/2 = 2.1 y; 135 Cs-t 1/2 = 2.3 My; and 137 Cs; t 1/2 = 30.2 y) [3,4], are problematic to selectively isolate, and are environmentally mobile, [5][6][7] leading to concerns about their long-term storage and disposal. Of these, 137 Cs is of greatest concern as a strong gamma emitter, with a combined β-γ thermal output of ca 70 mW/g [8].…”
Section: Introductionmentioning
confidence: 99%