2007
DOI: 10.1089/ees.2006.0096
|View full text |Cite
|
Sign up to set email alerts
|

Analysis and Kinetics of the Sequencing Batch Reactors

Abstract: Fundamental analysis and kinetics of treatment reactors are major topics in environmental engineering literature. These fundamental topics in reactor processes are well known for the ideal batch reactor, the continuous stirred tank reactor, and the plug flow reactor. The sequencing batch reactors (SBRs) are relatively new in the field, but are widely used. Despite the wide application of sequencing batch reactors in the field, information is lacking on the fundamental analysis and kinetics, especially with com… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 7 publications
0
4
0
Order By: Relevance
“…In addition, the reactants are placed at the beginning of the experiment, and the product is obtained at the end. The continuous oscillatory movement of the parallel‐plate geometry assists the local mixing of the reactants 34–36 …”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, the reactants are placed at the beginning of the experiment, and the product is obtained at the end. The continuous oscillatory movement of the parallel‐plate geometry assists the local mixing of the reactants 34–36 …”
Section: Resultsmentioning
confidence: 99%
“…The continuous oscillatory movement of the parallel-plate geometry assists the local mixing of the reactants. [34][35][36] Here, we investigate how continuous oscillation assists the gelation. To achieve this, along with usual time sweeps of continuous oscillation, we propose recording the gelation evolution in an interval fashion, that is, as an intermittent operation, in selected reaction conditions.…”
Section: Intermittent Versus Continuous Oscillatory Flowmentioning
confidence: 99%
“…A mathematical model was developed for the SBR system using these kinetics and assumptions by Udeme et al [35].…”
Section: Mathematical Model Developmentmentioning
confidence: 99%
“…Detailed cycle time configurations for the laboratory-scale SBRs can be 90 found in Table 1. During each cycle, 1.7 L effluent was decanted and replaced with synthetic sewage (i.e., 50% volumetric exchange ratio) giving a HRT of 1 day (Ndon, 2007). OECD synthetic sewage (Christofi et al, 2003;Gendig et al, 2003) was used as the feed for the lab-scale plant.…”
Section: Laboratory-scale Sequencing Batch Reactors (Sbrs)mentioning
confidence: 99%