2009
DOI: 10.1109/tie.2008.2011341
|View full text |Cite
|
Sign up to set email alerts
|

Analysis and Diagnostics of Adjacent and Nonadjacent Broken-Rotor-Bar Faults in Squirrel-Cage Induction Machines

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

5
54
0
1

Year Published

2014
2014
2024
2024

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 103 publications
(64 citation statements)
references
References 22 publications
5
54
0
1
Order By: Relevance
“…Moreover, previous works have shown that when there is a broken bar fault the neighboring bars are overcharged and are expected in most cases to break subsequently [7]. Despite this, some cases have been reported where the broken bars were not in adjacent positions but in random positions along the rotor circumference influencing negatively the diagnostic reliability of Motor Current Signature Analysis (MCSA) [7]- [10] for this fault.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, previous works have shown that when there is a broken bar fault the neighboring bars are overcharged and are expected in most cases to break subsequently [7]. Despite this, some cases have been reported where the broken bars were not in adjacent positions but in random positions along the rotor circumference influencing negatively the diagnostic reliability of Motor Current Signature Analysis (MCSA) [7]- [10] for this fault.…”
Section: Introductionmentioning
confidence: 99%
“…Despite this, some cases have been reported where the broken bars were not in adjacent positions but in random positions along the rotor circumference influencing negatively the diagnostic reliability of Motor Current Signature Analysis (MCSA) [7]- [10] for this fault.…”
Section: Introductionmentioning
confidence: 99%
“…[20], [21] also dealt with this issue by developing models where the case of nonadjacent breakages is taken into consideration. In [22] a thorough study of the induction motor with non-adjacent broken bars is carried out. Finally, in [16] a physical analysis of the air-gap magnetic anomaly for the case of any double bar breakage is performed.…”
Section: Introductionmentioning
confidence: 99%
“…Studies have shown that the breakage of a bar leads to overcharge of the adjacent bars, which are expected to break next [10]. However, industrial cases have shown that broken bars can exist at non-adjacent positions also [11]- [12]. Although in general, a broken rotor bar does not lead to an immediate fast catastrophic machine failure, this is not always the case.…”
Section: Introductionmentioning
confidence: 99%