2016 IEEE 6th International Conference on Power Systems (ICPS) 2016
DOI: 10.1109/icpes.2016.7584136
|View full text |Cite
|
Sign up to set email alerts
|

Analysis and design optimization of 765 kV transmission line based on electric and magnetic fields for different line configurations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 7 publications
0
5
0
1
Order By: Relevance
“…The transmission of alternating current electrical power [3], generates associated effects such as losses due to the corona effect, audible noise, and radio and television interference. Transmission lines are considered one of the principal sources of electric and magnetic fields [4]- [7]. The intensity of the fields emitted by these lines depends mainly on the transmitted current and their voltages.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…The transmission of alternating current electrical power [3], generates associated effects such as losses due to the corona effect, audible noise, and radio and television interference. Transmission lines are considered one of the principal sources of electric and magnetic fields [4]- [7]. The intensity of the fields emitted by these lines depends mainly on the transmitted current and their voltages.…”
Section: Introductionmentioning
confidence: 99%
“…In the easement zone or the right-of-way permit along the transmission line, the electric and magnetic field values must be lower than the reference levels specified above. If the rates of the fields are above the permissible limits, the design should be revised [4], [24].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Bu nedenle, iletim hattının çevresindeki güvenli alanın sadece atlama mesafesi dikkate alınarak değil, elektrik ve manyetik alan analizleri yapılarak belirlenmesi önem arz etmektedir. Bu konuda yapılan birçok benzetim ve deneysel çalışma mevcut olmasına karşın, farklı geometrilerde direkler kullanılması ve iletim gerilim seviyelerinin birbirlerinden farklı olması nedenleriyle hala çalışmaya ihtiyaç duyulmaktadır [2], [16], [20]- [25]. Teknik sorunlar ve/veya güvenlik nedenleriyle hatların yer değiştirilmesi (deplase) durumunda da analizlerin tekrarlanması gerekmektedir.…”
Section: Introductionunclassified
“…In recent years, several publications have been made to calculate the electric and magnetic fields created by power transmission lines. Most assume that the power lines are horizontal straight parallel to a flat ground, and the sag due to the power line weight is neglected or introduced by taking an average height between the maximum and the minimum height of the power line [6][7][8].…”
Section: Introductionmentioning
confidence: 99%