Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting
DOI: 10.1109/ias.1993.299011
|View full text |Cite
|
Sign up to set email alerts
|

Analysis and design of a new active power filter to cancel neutral current harmonics in three phase four wire electric distribution systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
20
0
2

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 83 publications
(22 citation statements)
references
References 4 publications
0
20
0
2
Order By: Relevance
“…To improve the quality of power supply three phase three wire (3P3W) DSTATCOM has been proposed. There are various topologies reported in the literature for three-phase four-wire system [4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21] such as a three single voltage source converter, split capacitor voltage source converter and four leg voltage source converter. The limitations of these control techniques are increase in KV A rating of the inverter and unequal voltages across the capacitor.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…To improve the quality of power supply three phase three wire (3P3W) DSTATCOM has been proposed. There are various topologies reported in the literature for three-phase four-wire system [4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21] such as a three single voltage source converter, split capacitor voltage source converter and four leg voltage source converter. The limitations of these control techniques are increase in KV A rating of the inverter and unequal voltages across the capacitor.…”
Section: Introductionmentioning
confidence: 99%
“…It is imperative for an optimized compensator to regulate DC bus capacitor voltage close to the reference value as far as possible. The capacitor voltage of DSTATCOM takes few cycles (normally [6][7][8] to settle under the disturbances in the loads [26]. The fuzzy logic and adaptive neuro fuzzy logic controllers may be used for improving the dynamics of traditional PI controller to have improved regulation on the DC bus voltage of DST ATCOM, eliminating higher overshoot and undershoot [28][29][30][31][32].…”
Section: Introductionmentioning
confidence: 99%
“…These harmonic currents cause excessive heating in distribution transformer, overheating of conductors, electrical noise and unnecessary tripping of circuit breakers in the system. Some of the remedial measures to minimize these harmonic currents include use of active and passive filters, use of zigzag transformer and use of separate neutrals for non-linear loads [2]- [3]. All these remedial measures lead to the increase in overall investment cost.…”
Section: Introductionmentioning
confidence: 99%
“…Problems like harmonics, inter-harmonics, flicker, notches, sags, swells can cause malfunction of equipment's based in microelectronic circuits that are very sensible to disturbances in the power supply [1]. Harmonic currents on the power system can distort the line voltage and lead to several adverse effects including equipment overheating, the malfunction of solid-state equipment and interference with communication systems [2].…”
Section: Introductionmentioning
confidence: 99%