Analyses and implications of V–I characteristic of PF insert conductor sample

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
5
0

Year Published

2005
2005
2011
2011

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 6 publications
(9 reference statements)
1
5
0
Order By: Relevance
“…The variation intensity scales with the nominal total current in BBIII ( fig.3 right) and it is a repeatable phenomenon, if the thermo-hydraulic conditions are the same. Such phenomenon has been previously observed also in the Poloidal Field Insert Sample, tested in the Sultan facility in 2004 [5], where considerable HP variations could be observed on both the wrapped leg side and, much more pronounced, on the un-wrapped leg side, where current re-distribution is more favoured. This further indicates that the observed signal variations are due to current transfer processes within the conductor cross-section.…”
Section: 2supporting
confidence: 70%
“…The variation intensity scales with the nominal total current in BBIII ( fig.3 right) and it is a repeatable phenomenon, if the thermo-hydraulic conditions are the same. Such phenomenon has been previously observed also in the Poloidal Field Insert Sample, tested in the Sultan facility in 2004 [5], where considerable HP variations could be observed on both the wrapped leg side and, much more pronounced, on the un-wrapped leg side, where current re-distribution is more favoured. This further indicates that the observed signal variations are due to current transfer processes within the conductor cross-section.…”
Section: 2supporting
confidence: 70%
“…Indeed, for the same quench current, a higher is observed at compared to [13]. The ITER design values for of the PF1&6 conductor at 45 kA, 6 T peak field, is 6.5 K, i.e.…”
Section: A DC Performancementioning
confidence: 84%
“…During runs at small, constant operating current and slowly increasing temperature, a slow change in the response of the Hall sensors indicates a smooth current re-distribution, [13], [18]. A small, saw-tooth ripple of Hall sensors signals at runs with high operating current is correlated with voltage spikes.…”
Section: Current Distributionmentioning
confidence: 96%
“…Otherwise the two conductors are identical. The DC performance of the PFIS conductors is limited by the occurrence of sudden take-offs above 35 kA in the left leg and above 45 kA in the right leg [6]. The values, found in the field range of 4 to 7 T, are 0.0116 (left leg) and 0.0145 T/kA (right leg).…”
Section: B Full-size Nbti Cic Conductorsmentioning
confidence: 97%
“…The conductor CON 3 shows an intermediate behavior, as indicated by the values listed in Table III. At sufficiently high overall current densities the phenomenon of sudden take-offs is generally observed in large CIC conductors [3]- [6], [10], [11]. Because of the interplay of the self-field and the cabling twist the local electric field varies strongly along the strand.…”
Section: A Sub-size Cic Conductorsmentioning
confidence: 99%