Analisis Partial Discharge Pada Saluran Kabel Tegangan Menengah 20 kV (Studi Assesmen SKTM di PT. PLN (Persero) UP3 Menteng)

Abstract: This study aims to determine the status of the cable condition to the emergence voltage of Partial Discharge, as well as the status of the cable to discharge the Partial Discharge. Measurements were made at PT PLN (Persero) UP3 Menteng on TD 09-PM 4A Segment Goat Feeders. This research uses a descriptive method. This study carried out measurements of the release of charge and voltage at each phase in the segment. After measuring the discharge of a single segment, data analysis is then performed to determine th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 0 publications
0
1
0
Order By: Relevance
“…Testing of ground cables (SKTM) is one way to see how the condition of the cables is considering the difficulty of detecting interference points so that preventive maintenance must be carried out to prevent SKTM interference [3]. The test guidelines on ground cables based on research journals [5] refer to IEC 60502 -2 in which one of the tests on ground cables (SKTM) is Tan Delta (TD). Tan Delta (TD) testing on cables serves to measure the magnitude of dielectric losses by looking at the extent of the delta angle shift, because the more the value of Tan Delta, the greater the dielectric losses on the cable and the faster the insulation of the cable undergoes aging [6,7].…”
Section: Introductionmentioning
confidence: 99%
“…Testing of ground cables (SKTM) is one way to see how the condition of the cables is considering the difficulty of detecting interference points so that preventive maintenance must be carried out to prevent SKTM interference [3]. The test guidelines on ground cables based on research journals [5] refer to IEC 60502 -2 in which one of the tests on ground cables (SKTM) is Tan Delta (TD). Tan Delta (TD) testing on cables serves to measure the magnitude of dielectric losses by looking at the extent of the delta angle shift, because the more the value of Tan Delta, the greater the dielectric losses on the cable and the faster the insulation of the cable undergoes aging [6,7].…”
Section: Introductionmentioning
confidence: 99%