2022
DOI: 10.1039/d2nj01051h
|View full text |Cite
|
Sign up to set email alerts
|

An α-naphtholphthalein-derived colorimetric fluorescent chemoprobe for the portable and visualized monitoring of Hg2+by the hydrolysis mechanism

Abstract: A novel fluorescent probe, 3,3'-(((1E,1'E)-((3-oxo-1,3-dihydroisobenzofuran-1,1-diyl)bis(1-hydroxynaphthalene-4,2-diyl))bis(methaneylylidene))bis(azaneylylidene))bis(2-aminomaleonitrile) (PM) was designed and successfully synthesized by Duff and Schiff-base condensation reactions, which consists of an α-naphtholphthalein scaffold and dual diaminomaleonitrile moieties. PM can be...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 88 publications
0
2
0
Order By: Relevance
“…It should be noted that eqn (10) is an approximation because only the first term of the Taylor series in eqn ( 8) is used. Anyway, eqn (10) is also helpful to explain the near-linear correlations between the light intensity or hue of the colorimetric images and concentration of target analytes in visible regions, [37][38][39][40][41][42][43][44][45] which are also due to the non-linear response of the CCD in the camera to light intensity (eqn (3)). But the value of G 3 is dependent on the values of G 1 and G 30 .…”
Section: Analytical Performance Of the Absorbance Modementioning
confidence: 99%
“…It should be noted that eqn (10) is an approximation because only the first term of the Taylor series in eqn ( 8) is used. Anyway, eqn (10) is also helpful to explain the near-linear correlations between the light intensity or hue of the colorimetric images and concentration of target analytes in visible regions, [37][38][39][40][41][42][43][44][45] which are also due to the non-linear response of the CCD in the camera to light intensity (eqn (3)). But the value of G 3 is dependent on the values of G 1 and G 30 .…”
Section: Analytical Performance Of the Absorbance Modementioning
confidence: 99%
“…A new fluorescent probe based on 3,3 -(((1E,1'E)-((3-oxo-1,3-dihydroisobenzofuran-1,1-diyl)bis(1-hydroxynaphthalene-4,2-diyl)))bis-(methanilyl-den))bis(azanilidene))bis-(2aminomaleonitrile) (PM) for the determination of Hg 2+ in an aqueous solution of THF was developed [10]. Thanks to its excellent fluorimetric properties, a portable smart platform with smartphone support was created for convenient, cost-effective, and reliable Hg 2+ detection.…”
Section: Introductionmentioning
confidence: 99%