2015 IEEE International Conference on Robotics and Automation (ICRA) 2015
DOI: 10.1109/icra.2015.7139894
|View full text |Cite
|
Sign up to set email alerts
|

An underactuated wearable arm-swing rehabilitator for gait training

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 18 publications
0
4
0
Order By: Relevance
“…The data-driven models simply require five independent variables-height, mass, gender, walking speed, and surface slope-to describe the shoulder-angle parameters such as frequency, amplitude, offset value, and phase, as well as the elbow-angle amplitude and offset value. The trajectories generated by Equation 10 may be useful for robotic [20,21] or other rehabilitation devices [6,12] that integrate arm swing in gait rehabilitation. Equation 10 can use a patient's physical information as primary inputs, and walking speed and surface slope can be measured during walking or be provided as predetermined values to generate desired shoulder-angle trajectories.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…The data-driven models simply require five independent variables-height, mass, gender, walking speed, and surface slope-to describe the shoulder-angle parameters such as frequency, amplitude, offset value, and phase, as well as the elbow-angle amplitude and offset value. The trajectories generated by Equation 10 may be useful for robotic [20,21] or other rehabilitation devices [6,12] that integrate arm swing in gait rehabilitation. Equation 10 can use a patient's physical information as primary inputs, and walking speed and surface slope can be measured during walking or be provided as predetermined values to generate desired shoulder-angle trajectories.…”
Section: Discussionmentioning
confidence: 99%
“…Equation 10 can use a patient's physical information as primary inputs, and walking speed and surface slope can be measured during walking or be provided as predetermined values to generate desired shoulder-angle trajectories. These trajectories can be applied to the patient by means of devices similar to what is proposed in [20,21] to correct the patient's arm swing for more effective gait rehabilitation.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations