2022
DOI: 10.1109/jsen.2022.3193049
|View full text |Cite
|
Sign up to set email alerts
|

An Uncalibrated and Accurate Robotic Puncture Method Under Respiratory Motion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 32 publications
0
4
0
Order By: Relevance
“…Both the median of angular errors and the maximum error value illustrate the high robustness of the proposed angular filtering method. And in the same experimental setting, the angle filtering based on SRUKF in literature 38 took 30 s and resulted in a positioning error of 0.46409° (0.00810 rad), highlighting the high accuracy and low time consumption of the angle filtering method proposed in this paper.…”
Section: Experiments and Resultsmentioning
confidence: 75%
See 1 more Smart Citation
“…Both the median of angular errors and the maximum error value illustrate the high robustness of the proposed angular filtering method. And in the same experimental setting, the angle filtering based on SRUKF in literature 38 took 30 s and resulted in a positioning error of 0.46409° (0.00810 rad), highlighting the high accuracy and low time consumption of the angle filtering method proposed in this paper.…”
Section: Experiments and Resultsmentioning
confidence: 75%
“…It can be observed that the position filtering method we proposed also possesses high robustness. In contrast, the position filtering method proposed in literature 38 took 50 s and had an average error of 0.44580 mm. Our method takes only approximately 13 s, highlighting the advantage of our proposed position filtering method in terms of low processing time and high accuracy.…”
Section: Experiments and Resultsmentioning
confidence: 99%
“…Yan et al [ 100 ] proposed an uncalibrated robotic puncture method based on respiratory motion. This method introduces an efficient approach for the online estimation of the Jacobian matrix using the Square Root Unscented Kalman Filter.…”
Section: Optimization Methods Of Medical Image Navigation Technology ...mentioning
confidence: 99%
“…In thoracic and abdominal puncture surgery, a robotic puncture system (RPS) has the advantages of accurate positioning, flexible movement, and stable operation, and various tissue biopsy diagnosis and surgical scenarios can produce more significant therapeutic impacts. Due to the characteristics of rapid speed, short cycle, and multi-dimensional displacement, respiratory movement may lead to systematic deviation of the target area of thoracoabdominal puncture and affect the therapeutic effect [ 6 ].…”
Section: Introductionmentioning