2012 IEEE Biomedical Circuits and Systems Conference (BioCAS) 2012
DOI: 10.1109/biocas.2012.6418507
|View full text |Cite
|
Sign up to set email alerts
|

An ultra-low noise current source for magnetoresistive biosensors biasing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
1
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 11 publications
0
5
0
Order By: Relevance
“…The current sources' noise characteristics achieved in Ciofi et al (1997) and Scandurra et al (2014) meet the requirements for the DCCS (Table 1). Table 1 also shows that the noise of the current source (Costa et al, 2012), which is built using semiconductor voltage reference, exceeds the specified limits several times over. Devices that developed by Ciofi et al (1997) and Scandurra et al (2014) are designed to work in the laboratory in a relatively narrow temperature range.…”
Section: Development Of Digitally Controlled Current Sourcementioning
confidence: 98%
See 2 more Smart Citations
“…The current sources' noise characteristics achieved in Ciofi et al (1997) and Scandurra et al (2014) meet the requirements for the DCCS (Table 1). Table 1 also shows that the noise of the current source (Costa et al, 2012), which is built using semiconductor voltage reference, exceeds the specified limits several times over. Devices that developed by Ciofi et al (1997) and Scandurra et al (2014) are designed to work in the laboratory in a relatively narrow temperature range.…”
Section: Development Of Digitally Controlled Current Sourcementioning
confidence: 98%
“…As a digital-to-analog converter, one of the best monolithic models -a 20 bit DAC AD5791 with temperature drift 0.05 ppm • C −1 -was selected (Egan, 2010). As the data sheet of this component (Analog Devices, Inc., 2013) contains incomplete information regarding the noise level at low frequencies, these characteristics were examined in two circuit configurations: with bipolar (Fig.…”
Section: Dac Configuration -Bipolar Vs Unipolar Reference Inputmentioning
confidence: 99%
See 1 more Smart Citation
“…In the case of current sources, the noise also depends on the output current, load impedance and frequency. Consequently, an adequately selected device can obtain output current noise as low as a few pA/ √ Hz [53][54][55][56][57][58][59]. The selected amplifier and its performances are crucial elements that usually set system capabilities, such as noise, bandwidth and input signal range.…”
Section: Noise Measurementsmentioning
confidence: 99%
“…The current sources' noise characteristics achieved in (Ciofi et al, 1997;Scandurra et al, 2014) meet the requirements to the DCCS (Table 1). Table 1 also shows that the noise of the current source (Costa et al, 2012), Geosci. Instrum.…”
Section: Development Of Digitally Controlled Current Sourcementioning