1994
DOI: 10.1016/0378-7796(94)90043-4
|View full text |Cite
|
Sign up to set email alerts
|

An output feedback static var controller for the damping of generator oscillations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

1998
1998
2014
2014

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(8 citation statements)
references
References 20 publications
0
8
0
Order By: Relevance
“…Note that for this linearised power system model, controllers are designed and put in loop with the plant model so that when there are any disturbances taking place like the faults, the oscillations are reduced quickly in no time, thus becoming a closed-loop feedback control system (Lee and Liu, 1994). The simulation parameters of the three-machine, nine-bus interconnected power system model with four loads L1-L4 and two UPFCs are given in Table 1 (Cai and Erlich, 2002).…”
Section: Figurementioning
confidence: 99%
See 1 more Smart Citation
“…Note that for this linearised power system model, controllers are designed and put in loop with the plant model so that when there are any disturbances taking place like the faults, the oscillations are reduced quickly in no time, thus becoming a closed-loop feedback control system (Lee and Liu, 1994). The simulation parameters of the three-machine, nine-bus interconnected power system model with four loads L1-L4 and two UPFCs are given in Table 1 (Cai and Erlich, 2002).…”
Section: Figurementioning
confidence: 99%
“…The first-generation (G1) FACTS devices include SVC, TCPS and TCSC. It has been found that SVCs can be effective in damping power system oscillations if a supplementary feedback signal is applied (Hammad, 1986;Lee and Liu, 1994). Compared with other FACTS devices, little attention has been paid to TCPS modelling and control.…”
Section: Introductionmentioning
confidence: 99%
“…According to [5][6][7][8] the most suitable supplementary input signals are locally measured transmission line-current magnitude or locally measured active power. In [9,10] used generator angular speed as a supplementary input signal. proposed a method for selecting suitable feedback signal to FACTS controllers for improving damping oscillations base on four indicators for both MIMO and SISO system.…”
Section: Introductionmentioning
confidence: 99%
“…According to Zhou, 1993) the best input signals for power oscillation controler are locally measured transmission line-current magnitude or locally measured active power. Lee and Liu (1994) and Zhou (1993) applied the remote signal that is generator angular speed as a auxiliary input signal.…”
Section: Introductionmentioning
confidence: 99%