2019
DOI: 10.1016/j.ijepes.2018.12.007
|View full text |Cite
|
Sign up to set email alerts
|

An optimized direct control method applied to multilevel inverter for microgrid power quality enhancement

Abstract: Multifunctional DGs and active power filters have become a mature technology in recent years, so in this paper, an optimized current control method for a multilevel converter is proposed to overcome harmonic current tracking inefficiency of previous control methods in online harmonic compensation applications in microgrids. This control method is applicable for grid-connected inverter-based multifunctional Distributed Generation (DG) converters. It could also be used in active power filter applications which n… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 42 publications
(15 citation statements)
references
References 45 publications
0
12
0
Order By: Relevance
“…Several switching methods have been presented for multilevel inverters in the literature, 46,47 however in this paper, the nearest level control (NLC) method presented in Reference 21, is used to control the proposed multilevel topology where, α1,2true,˙ refer to switching angles. To design the value of utilized capacitors ( C x ), the voltage ripple should be calculated which is calculated as: normalΔUCx=1()2πfref×CxαnαmiCxd()ωt. In which αn and αm are the switching angels.…”
Section: Basic Unit Of Suggested Multilevel Invertermentioning
confidence: 99%
“…Several switching methods have been presented for multilevel inverters in the literature, 46,47 however in this paper, the nearest level control (NLC) method presented in Reference 21, is used to control the proposed multilevel topology where, α1,2true,˙ refer to switching angles. To design the value of utilized capacitors ( C x ), the voltage ripple should be calculated which is calculated as: normalΔUCx=1()2πfref×CxαnαmiCxd()ωt. In which αn and αm are the switching angels.…”
Section: Basic Unit Of Suggested Multilevel Invertermentioning
confidence: 99%
“…The delay compensation not only makes up for computation time of the algorithm, but also effectively raises the performance of current tracking for motor operating on fault state and condition suddenly alteration. According to principle of delay compensation [24], all switch control signals are used to calculate the predictive current at the (k + 2)-th instant:…”
Section: Current Tracking Performancementioning
confidence: 99%
“…A current tracking method based on FSMPC is presented in [23], which improves the accuracy and rapidity of current tracking when compare to PI modulation. In [24], an optimized current control method with delay compensation is proposed to overcome harmonic current in distributed generation converters, and reference current at the next instant is tracked by controlling one switch control signal to generate one basic space voltage vector during every sampling period. However, these presented motor emulators only pursuit current tracking performance as the control object, while power loss of motor emulators is severely neglected.…”
Section: Introductionmentioning
confidence: 99%
“…In recent years, many solutions have been proposed to address power quality issues. Power conditioning systems, power filters, and other tools are used to improve the quality of the electricity [25]- [28].…”
Section: Introductionmentioning
confidence: 99%