2018
DOI: 10.1016/j.talanta.2017.08.098
|View full text |Cite
|
Sign up to set email alerts
|

An on-line coupling of nanofibrous extraction with column-switching high performance liquid chromatography – A case study on the determination of bisphenol A in environmental water samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
12
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 39 publications
(12 citation statements)
references
References 21 publications
0
12
0
Order By: Relevance
“…Among these kinetic models, the high correlation coefficient ( R > 0.98) and the small value of the root mean square errors (0.63) corresponded to the pseudo‐second‐order model; this showed that that this model fit the kinetic data well. This kinetic model indicated that the rate‐limiting step controlling the BPA adsorption process was chemisorption interaction.…”
Section: Resultsmentioning
confidence: 87%
See 1 more Smart Citation
“…Among these kinetic models, the high correlation coefficient ( R > 0.98) and the small value of the root mean square errors (0.63) corresponded to the pseudo‐second‐order model; this showed that that this model fit the kinetic data well. This kinetic model indicated that the rate‐limiting step controlling the BPA adsorption process was chemisorption interaction.…”
Section: Resultsmentioning
confidence: 87%
“…In recent years, the search for effective and novel adsorbent materials has been a new challenge in nanoscience and nanotechnology . Among different nanostructured materials, nanofiber mats produced by the electrospinning technique have attracted much attention because of their structural characteristics, such as their high surface area, high porosity and interconnectivity, good structural stability, and controllable thickness …”
Section: Introductionmentioning
confidence: 99%
“…Neither extraction efficiency nor the back pressure of PCL composite sorbent had changed during these experiments. Thus, our composite micro/nanofibrous sorbent is better suited for the extensive use in high-pressure liquid chromatography systems than nanofibers reported elsewhere [ 31 ]. The microfibers represent a stable scaffold resistant to the high pressure while, simultaneously, the large surface area to volume ratio of the nanofibers contributes to the high extraction efficiency.…”
Section: Resultsmentioning
confidence: 99%
“…Nanofiber polymers that have demonstrated an excellent potential for extraction purposes were used as sorbents for online SPE‐UHPLC system and the system was tested for the determination of bisphenol A in river water samples . The LOD and LOQ of the purposed method reached to 0.6 and 2 μg/L with a 50 μL sample injection.…”
Section: New Trends For Online Coupling Techniques Of Sample Preparatmentioning
confidence: 99%