2008
DOI: 10.1016/j.jbiomech.2007.09.018
|View full text |Cite
|
Sign up to set email alerts
|

An MRI-compatible foot-loading device for assessment of internal tissue deformation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
29
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 32 publications
(29 citation statements)
references
References 10 publications
(10 reference statements)
0
29
0
Order By: Relevance
“…Novel computational approaches have been tried, validated and used in recent publications dealing with neural networks (Betker AL et al, 2005), fuzzy logics (Senanayake CM, Senanayake SM, 2010 a), cluster analysis (Giacomozzi C., Martelli F, 2006), finite element models (Shiang TY, 1997;Petre M et al, 2008;Gu YD et al, 2010;Chen WM et al, 2010), image processing techniques (Pataky TC et al, 2009;Oliveira FP, Tavares JM, 2010) and so on. Usually, the inputs of such models are represented by the above traditional parameters, their reliability strongly relying on the quality and reliability of raw data.…”
Section: Force-time Integral or Impulse (Usually Indicated As Fti)mentioning
confidence: 99%
“…Novel computational approaches have been tried, validated and used in recent publications dealing with neural networks (Betker AL et al, 2005), fuzzy logics (Senanayake CM, Senanayake SM, 2010 a), cluster analysis (Giacomozzi C., Martelli F, 2006), finite element models (Shiang TY, 1997;Petre M et al, 2008;Gu YD et al, 2010;Chen WM et al, 2010), image processing techniques (Pataky TC et al, 2009;Oliveira FP, Tavares JM, 2010) and so on. Usually, the inputs of such models are represented by the above traditional parameters, their reliability strongly relying on the quality and reliability of raw data.…”
Section: Force-time Integral or Impulse (Usually Indicated As Fti)mentioning
confidence: 99%
“…In addition, as is relevant here, they have been employed for non-invasive investigation of soft tissue biomechanics (e.g. [2,18,[22][23][24][25][26]). …”
Section: Introductionmentioning
confidence: 99%
“…[18,[22][23][24][25][26][27]), however their design is often tailored to suit their particular application (e.g. ranging from rat lower limb [18], to human footpad [25] and pigs buttock [23]) which, to date, has not included indentation of the upper arm. Despite this, a brief discussion of current soft tissue loading systems for the MRI environment is presented here.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations