2001
DOI: 10.1109/23.940147
|View full text |Cite
|
Sign up to set email alerts
|

An LSO scintillator array for a PET detector module with depth of interaction measurement

Abstract: Abstract--We present construction methods and performance results for a production scintillator array of 6 4 optically isolated, 3 mm x 3 mm x 30 mm sized LSO crystals. This scintillator array has been developed for a PET detector module consisting of the 8x8 LSO array coupled on one end to a single photomultiplier tube (PMT) and on the opposite end to a 64 pixel array of silicon photodiodes (PD). The PMT provides an accurate timing pulse and initial energy discrimination, the PD identifies the crystal of inte… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
43
0

Year Published

2004
2004
2008
2008

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 68 publications
(46 citation statements)
references
References 17 publications
1
43
0
Order By: Relevance
“…This degradation is also due to the decreased signal to noise ratio as described for energy resolution in the previous section. The DOI resolution has improved in comparison to a previous prototype module, which had 6 to 15 mm DOI resolution [4]. This improvement may be attributed to the lower electronic noise of the PETRIC.…”
Section: B Doi Resolutionmentioning
confidence: 77%
See 3 more Smart Citations
“…This degradation is also due to the decreased signal to noise ratio as described for energy resolution in the previous section. The DOI resolution has improved in comparison to a previous prototype module, which had 6 to 15 mm DOI resolution [4]. This improvement may be attributed to the lower electronic noise of the PETRIC.…”
Section: B Doi Resolutionmentioning
confidence: 77%
“…The LBNL PEM detector consists of 64 3 mm × 3 mm × 30 mm LSO crystals coupled to a single photomultiplier tube and an 8×8 silicon photodiode array [4]. The photomultiplier tube provides accurate timing.…”
Section: Index Terms-biomedical Imaging Calibration Detectors Deptmentioning
confidence: 99%
See 2 more Smart Citations
“…For instance, light sharing detectors are based on the deployment of photodetectors on both the back and the front side of the scintillator crystal ( Fig. 4.18d) and estimate DOI depending on the ratio of total energy collected in both sides [249,250]. Also, continuous cubic detectors have been proposed with photodetectors coupled to side borders ( Fig.…”
Section: Doi Estimationmentioning
confidence: 99%