An Isolated Soft-Switched High-Power-Factor Rectifier Based on the Asymmetrical Half-Bridge Flyback Converter

Abstract: This article presents the analysis and design of a high-power-factor rectifier that integrates a discontinuous conduction mode operated Boost input cell with an asymmetrical half-bridge flyback converter (AHBFC). The particular connection of the dc-dc stage with the boost cell makes the dc link voltage decrease at light load, thus naturally limiting the switches' voltage stress. A suitable design procedure is described that accounts for the resonant nature of the AHBFC, and allows to calculate all converter pa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(5 citation statements)
references
References 32 publications
0
4
0
Order By: Relevance
“…For the calculation of D g , the estimated v s and v bus help to shape the envelope of the input current while k iv controls the magnitude of the input current. The constant V o within a line period is achieved by actively estimating the instantaneous v bus using the processed sample signals V bus.avg , V sp , and t. According to v bus , V bus.avg , D g , and k out , the appropriate D h to output constant V o could be calculated using (37) or (38). For the calculation of D h , the estimated v bus , processed sampled V bus.avg , and previously calculated D g help to eliminate the double-line ripple of the output voltage while k out controls the output voltage level.…”
Section: Control Strategy Of the Single-stage Topologymentioning
confidence: 99%
“…For the calculation of D g , the estimated v s and v bus help to shape the envelope of the input current while k iv controls the magnitude of the input current. The constant V o within a line period is achieved by actively estimating the instantaneous v bus using the processed sample signals V bus.avg , V sp , and t. According to v bus , V bus.avg , D g , and k out , the appropriate D h to output constant V o could be calculated using (37) or (38). For the calculation of D h , the estimated v bus , processed sampled V bus.avg , and previously calculated D g help to eliminate the double-line ripple of the output voltage while k out controls the output voltage level.…”
Section: Control Strategy Of the Single-stage Topologymentioning
confidence: 99%
“…A comprehensive study in transient, steady-state, and switching dynamics is presented. [33] focuses on the analysis and design of a softswitched clamped-resonant interleaved boost converter. It could be valuable for those interested in soft-switching techniques and resonant converters.…”
Section: A Significance Of Boost Convertersmentioning
confidence: 99%
“…Requirements are high efficiency, reliability and power factor on one side and low weight and cost on the other side [4 -9]. In the references could be found many rectifying topologies [10,11]. One of the recent proposed topologies has low switch number, and power factor correction [12,13].…”
Section: Introductionmentioning