Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2002
DOI: 10.1006/jcat.2002.3645
|View full text |Cite
|
Sign up to set email alerts
|

An Investigation of the NO/H2/O2 (Lean De-NOx) Reaction on a Highly Active and Selective Pt/La0.7Sr0.2Ce0.1FeO3 Catalyst at Low Temperatures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
66
1

Year Published

2004
2004
2015
2015

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 126 publications
(76 citation statements)
references
References 40 publications
2
66
1
Order By: Relevance
“…The flow-system used for conducting catalytic measurements at 1 atm total pressure consisted of a mass flow measuring and control system (MKS, Model 247C), mixing chambers, a quartz fixed-bed micro-reactor (2 mL nominal volume), and a gas chromatograph/mass spectrometer (GC/MS) (Hewlett Packard 5890, Series II Plus/Omnistar-Balzers) analysis system. The flow system, the micro-reactor and the analysis system used have been recently described in detail (Costa et al 2001). The feed stream consisting of 0.25% NO, 1.0% H 2 , 5% O 2 and He as balance gas was used in all experiments.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The flow-system used for conducting catalytic measurements at 1 atm total pressure consisted of a mass flow measuring and control system (MKS, Model 247C), mixing chambers, a quartz fixed-bed micro-reactor (2 mL nominal volume), and a gas chromatograph/mass spectrometer (GC/MS) (Hewlett Packard 5890, Series II Plus/Omnistar-Balzers) analysis system. The flow system, the micro-reactor and the analysis system used have been recently described in detail (Costa et al 2001). The feed stream consisting of 0.25% NO, 1.0% H 2 , 5% O 2 and He as balance gas was used in all experiments.…”
Section: Methodsmentioning
confidence: 99%
“…The amount of supported-Pt catalyst sample used for catalytic experiments was 0.15 g and the total flow rate was 100 NmL/min, resulting in a gas hourly space velocity (GHSV) of about 80.000 h -1 . For the experiments to study the effects of H 2 O in the feed stream on the NO conversion and N 2 selectivity, a feed gas mixture containing about 5 mol% H 2 O was prepared as previously described (Costa et al 2001).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Costa et al studied 0.1 wt.% Pt supported on La 0.5 Ce 0.5 MnO 3 perovskite type material for the NO/H 2 /O 2 reaction in the 100-400°C range [24]. In another report 0.1 wt.% Pt supported La 0.7 Sr 0.2 Ce 0.1 FeO 3 perovskite catalyst has been studied for the same reaction [25]. In fact, it has been shown that the Pd/LaCoO 3 exhibits better activity as compared to Pd/Al 2 O 3 .…”
Section: Introductionmentioning
confidence: 95%