1968
DOI: 10.1115/1.3605204
|View full text |Cite
|
Sign up to set email alerts
|

An Investigation of Pulsations in the Boiler Feed System of a Central Power Station

Abstract: A field investigation was made to determine the source and character of pressure pulsations in the boiler feed system of a central power station. By systematic equipment elimination, it was concluded that the oscillation are caused by rotating stall in the boiler feed pump as it enters into resonance with the piping circuit. An analysis is carried out of the equivalent linear system under harmonic conditions. The analytical model provides reasonable agreement with the observations for the three tested piping c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

1981
1981
2021
2021

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…9,31,32 Rotating stall may also resonate with an acoustic mode of the inlet piping system, leading to greater pulsations of the whole system. For example, Dussourd 39 identiEed such kind of vibrations in a boiler feeding system. For a comprehensive review of rotating stall, readers are referred to Greitzer.…”
Section: Basics Of Rotating Stallmentioning
confidence: 99%
“…9,31,32 Rotating stall may also resonate with an acoustic mode of the inlet piping system, leading to greater pulsations of the whole system. For example, Dussourd 39 identiEed such kind of vibrations in a boiler feeding system. For a comprehensive review of rotating stall, readers are referred to Greitzer.…”
Section: Basics Of Rotating Stallmentioning
confidence: 99%
“…Dussourd (1968) identified such a problem in a boiler feed system where the rotating stall frequency was in the range 0.15 ? Dussourd (1968) identified such a problem in a boiler feed system where the rotating stall frequency was in the range 0.15 ?…”
Section: Rotating Stallmentioning
confidence: 99%
“…51 and described in the section on pressure drop oscillations. Other references on the general topic are [175] which gives a discussion of pulsations in the boiler feed system of a pumping station due to rotating stall in one of the pumps, [176] which presents graphic descriptions of some of the consequences of instabilities in power stations, and [177] which discusses large amplitude low frequency pulsations which occur in centrifugal pumping systems.…”
Section: Self-excited Oscillations In Hydraulic Systems and Othementioning
confidence: 99%