The platform will undergo maintenance on Sep 14 at about 7:45 AM EST and will be unavailable for approximately 2 hours.
2020 International SAUPEC/RobMech/PRASA Conference 2020
DOI: 10.1109/saupec/robmech/prasa48453.2020.9041014
|View full text |Cite
|
Sign up to set email alerts
|

An Investigation Into an Appropriate optical Calibration Source for a Corona Camera

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 9 publications
0
3
0
Order By: Relevance
“…There are various types of sources that are proposed for the calibration of SBUV cameras such as Blackbody radiators, deuterium lamps, laser, electrical discharge, and specially adapted LED sources [20,21] SBUV cameras have different output responses to each of these sources, which are attributed to the difference between the spectrum of the source and the cameras themselves. The methods and proposals to solve the spectral mismatching will be discussed in the future as an additional step to improve accuracy.…”
Section: Calibration Sourcementioning
confidence: 99%
See 1 more Smart Citation
“…There are various types of sources that are proposed for the calibration of SBUV cameras such as Blackbody radiators, deuterium lamps, laser, electrical discharge, and specially adapted LED sources [20,21] SBUV cameras have different output responses to each of these sources, which are attributed to the difference between the spectrum of the source and the cameras themselves. The methods and proposals to solve the spectral mismatching will be discussed in the future as an additional step to improve accuracy.…”
Section: Calibration Sourcementioning
confidence: 99%
“…Relations (1) to (5) need to be manipulated in such a manner that the measured digital level can be converted to an optical energy flux format relation [4,20]. However, part of the solution (source vs. camera output) is in the enclosed form of an integral that needs to be solved.…”
Section: Calibration Curvesmentioning
confidence: 99%
“…However, despite its obvious importance, this parameter is not presented in data sheets of typical SBUV cameras [1][2][3][4][5][6]. More importantly, the available scientific papers devoted to the characteristics of SBUV cameras did not present any concept on how to measure this parameter [7][8][9][10][11]. In such a situation this paper presents the concept (definition, measurement method, test equipment, interpretation of results) of measuring solar sensitivity of SBUV cameras.…”
Section: Introductionmentioning
confidence: 99%