2020
DOI: 10.1016/j.elecom.2020.106862
|View full text |Cite
|
Sign up to set email alerts
|

An inverse-designed electrochemical platform for analytical applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
15
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 14 publications
(15 citation statements)
references
References 27 publications
0
15
0
Order By: Relevance
“…The following current results were obtained: 29.4 ± 0.5, 40 ± 1, 35 ± 9 nA, and 132 ± 14 nA for SWNTs, MWNTs, GNPs, and bare SPEs, respectively. By using the standard deviation [ 50 ] as the index of signal/noise ratio, it was possible to ascertain that the modification with CNMs produced a more dependable electrochemical device with an important minimization of capacitive current. After that, six different platforms ( n = 6) for each modified-SPEs were analyzed voltammetrically (CV) using the reversible couple (10 mM) [Fe(CN) 6 ] 3-/4- as an electroactive reporter.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The following current results were obtained: 29.4 ± 0.5, 40 ± 1, 35 ± 9 nA, and 132 ± 14 nA for SWNTs, MWNTs, GNPs, and bare SPEs, respectively. By using the standard deviation [ 50 ] as the index of signal/noise ratio, it was possible to ascertain that the modification with CNMs produced a more dependable electrochemical device with an important minimization of capacitive current. After that, six different platforms ( n = 6) for each modified-SPEs were analyzed voltammetrically (CV) using the reversible couple (10 mM) [Fe(CN) 6 ] 3-/4- as an electroactive reporter.…”
Section: Resultsmentioning
confidence: 99%
“…Spectrophotometric methods have also been used [ 44 , 45 , 46 , 47 , 48 , 49 ]. Although these methods to measure HQ and BQ levels have been demonstrated to be effective, they still require a minimum of in-presence sample processing and high employment of reagents and time [ 50 , 51 ]. In this context, electrochemical sensors represent a valid alternative to the traditional staple techniques due to their instrumental simplicity, cost-effectiveness, and portability [ 50 , 52 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Taking a look at the literature, Cancelliere et al used biochar obtained from brewer waste to improve the properties of an interesting inverse-designed graphite SPE; using Fe­[(CN) 6 ] 4–/3– as a redox probe, Δ E = 205 mV (50 mV s –1 ) and K 0 of 1.8 × 10 –3 cm s –1 were obtained. The same group, using another type of biochar, demonstrated comparable results, modifying graphite-SPE ( K 0 = 2.3 × 10 –3 cm s –1 ) .…”
Section: Resultsmentioning
confidence: 99%
“…Critical importance in electroanalytical measurement is given to the magnitude of the electrochemical response and its reproducibility. There are different ways in which this target can be achieved: first, improving the electron transfer conductivity of the transducers; second, reshaping the geometry of the working or reference electrode [ 1 ] (avoiding post-printing modification procedure); finally, attempting to alter the surface area of the electrode. Among these, the electronic transfer is the cardinal attribute behind all the different electrochemical sensors.…”
Section: Introductionmentioning
confidence: 99%