2003
DOI: 10.1063/1.1627240
|View full text |Cite
|
Sign up to set email alerts
|

An International Star Intercomparison of Low-Temperature Fixed Points Using Sealed Triple-Point Cells

Abstract: Bilateral Intercomparison of the ITS-90 Realisations in the Range from −189.3442 °C (Triple Point of Argon) to 961.78 °C (Freezing Point of Silver) between the MIRS/FE-LMK (Slovenia) and the PTB (Germany) AIP Conf.Abstract. An overview of the main results of an international star intercomparison of low-temperature fixed points is given. Between 1997 and 2002, 52 sealed triple-point cells (STPCs) of the thirteen laboratories represented by the authors have been investigated at PTB. The STPCs are used to realise… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2003
2003
2017
2017

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(11 citation statements)
references
References 5 publications
0
11
0
Order By: Relevance
“…This extension has no effect on the results for the thermodynamic temperature T, which is deduced from A 1 . In this paper, the high-temperature working equation (equation (25) in [12]) has to be applied only for the determination of κ eff at the TPW.…”
Section: Dcgt Principle and Input Datamentioning
confidence: 99%
“…This extension has no effect on the results for the thermodynamic temperature T, which is deduced from A 1 . In this paper, the high-temperature working equation (equation (25) in [12]) has to be applied only for the determination of κ eff at the TPW.…”
Section: Dcgt Principle and Input Datamentioning
confidence: 99%
“…• Parameters of elements for multi-compartment cells [4,8,10,13]. • Universal and special properties of the fixed-point substances [5,8,25,28,29]. • Influence of the freezing and annealing conditions on the thermal recovery, the internal thermal resistance and the equilibrium MCs, especially for neon STPCs [28].…”
Section: Overview Of the Previous Resultsmentioning
confidence: 99%
“…The measurement protocol has been established in [25] and later on slightly improved, see [4,5,26,27]. To measure an MC applying the calorimetric method, the sample was heated through the solid-to-liquid phase transition under nearly isothermal conditions by the intermittent application of heat.…”
Section: Comparison Measurements and Evaluationmentioning
confidence: 99%
“…These cells were tested during the EU 'Multicells' project, G6RD-CT-1999-00114 [6]. The triple point of oxygen was realized in the IMGC cell no 202 3-IX-76, which was included in the EUROMET project 377 [7]. The cells were placed in an adiabatic cryostat as described in [8].…”
Section: Measurements Performed At Intibsmentioning
confidence: 99%
“…To realize the mercury and water triple points, cell Hg 220 and H 2 O cell B11/50/465 were used with their respective baths manufactured by ISOTECH. Both of these cells are being tested in bilateral comparisons under the EUROMET projects 895 6 and 914 7 .…”
Section: Measurements Performed At Intibsmentioning
confidence: 99%