An Integrated Simulation Approach and Experimental Research on Microwave Induced Thermo-Acoustic Tomography System

Abstract: Abstract-Microwave induced thermo-acoustic tomography (MI-TAT) has great potential in early breast cancer detection because it utilizes the advantages of both microwave imaging and ultrasound imaging. In this paper, a fast and efficient simulation approach based on a hybrid method which combines finite integration time domain (FITD) method and pseudo-spectral time domain (PSTD) method is developed. By using this approach, energy deposition of biology tissue illuminated by electromagnetic fields can be accurate… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7
2

Relationship

3
6

Authors

Journals

citations
Cited by 21 publications
(6 citation statements)
references
References 27 publications
(38 reference statements)
0
6
0
Order By: Relevance
“…Combining the measured results with the reported data of tissue properties with CNTs, a numerical breast model is established. An integrated simulation approach [18] including microwave field and acoustic field is performed to verify the imaging contrast enhancement. To better evaluate the performance of CNTs, tissue mimicking materials with different concentrations of CNTs are made and tested in a MITAT experimental system, corresponding with the simulation results to evaluate the imaging contrast enhancement caused by CNTs.…”
Section: Evaluation Of Contrast Enhancement By Carbonmentioning
confidence: 99%
“…Combining the measured results with the reported data of tissue properties with CNTs, a numerical breast model is established. An integrated simulation approach [18] including microwave field and acoustic field is performed to verify the imaging contrast enhancement. To better evaluate the performance of CNTs, tissue mimicking materials with different concentrations of CNTs are made and tested in a MITAT experimental system, corresponding with the simulation results to evaluate the imaging contrast enhancement caused by CNTs.…”
Section: Evaluation Of Contrast Enhancement By Carbonmentioning
confidence: 99%
“…Fig. 4(b) shows a sketch map of the MITAT system which has been illustrated in [20,21]. The pulse width of the microwave generator is adjustable.…”
Section: Methodsmentioning
confidence: 99%
“…So, the microwave absorption distribution is mainly determined by the conductivity distribution. By using the integrated simulation approach, 31 the induced ultrasonic signals are generated and received by the surrounded transducer array. The transducer array has a total of 200 elements.…”
Section: D a Tumor Target Embedded In The Anatomically Realistic Nmentioning
confidence: 99%