2023
DOI: 10.3390/bios13080790
|View full text |Cite
|
Sign up to set email alerts
|

An Integrated Microfluidic Biosensing System Based on a Versatile Valve and Recombinase Polymerase Amplification for Rapid and Sensitive Detection of Salmonella typhimurium

Abstract: Detecting foodborne pathogens on-site is crucial for ensuring food safety, necessitating the development of rapid, cost-effective, highly sensitive, and portable devices. This paper presents an integrated microfluidic biosensing system designed for the rapid and sensitive detection of Salmonella typhimurium (S. typhimurium). The biosensing system comprises a microfluidic chip with a versatile valve, a recombinase polymerase amplification (RPA) for nucleic acid detection, and a customized real-time fluorescence… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 39 publications
(40 reference statements)
0
1
0
Order By: Relevance
“…Recently, the RPA method has been used for the detection of Salmonella enterica [ 15 ]. Moreover, Yan Jin and colleagues have developed a RPA-based platform for Salmonella Typhimurium detection ( S. Typhimurium), which could work at concentrations as low as 1.0 × 10 2 copies/µL within 30 min [ 34 ]. However, efforts are still needed to eliminate the undesired nonspecific amplification and false-positive results.…”
Section: Discussionmentioning
confidence: 99%
“…Recently, the RPA method has been used for the detection of Salmonella enterica [ 15 ]. Moreover, Yan Jin and colleagues have developed a RPA-based platform for Salmonella Typhimurium detection ( S. Typhimurium), which could work at concentrations as low as 1.0 × 10 2 copies/µL within 30 min [ 34 ]. However, efforts are still needed to eliminate the undesired nonspecific amplification and false-positive results.…”
Section: Discussionmentioning
confidence: 99%
“…In another novel study, a PDMS microfluidic chip was adhered to a glass substrate and implanted with a versatile valve for liquid mixing. 66 This chip displayed the detection of Salmonella typhimurium as low as 1.0 × 102 copies/µL within 30 min, offering significantly simplified and quicker on‐site detection of Salmonella compared to PCR‐based methods. Furthermore, paper microfluidic devices developed within the past few years have demonstrated the detection of L. monocytogenes, Campylobacter jejuni, S. aureus and Vibrio parahaemolyticus .…”
Section: Applications For Food Safetymentioning
confidence: 99%
“…(Reproduced with permission ,72 Copyright 2021, Microchemical Journal).represents the most ubiquitous foodborne pathogen. In another novel study, a PDMS microfluidic chip was adhered to a glass substrate and implanted with a versatile valve for liquid mixing 66. This chip displayed the detection of Salmonella typhimurium as low as 1.0 × 102 copies/µL within 30 min, offering significantly simplified and quicker on-site detection of Salmonella compared to PCR-based methods.…”
mentioning