2002
DOI: 10.1016/s0376-7388(02)00369-1
|View full text |Cite
|
Sign up to set email alerts
|

An integrated centrifugation–ultrafiltration system in the treatment of olive mill wastewater

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
73
1
9

Year Published

2005
2005
2021
2021

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 190 publications
(90 citation statements)
references
References 18 publications
1
73
1
9
Order By: Relevance
“…They proposed a pretreatment consisting of oil removal and suspended solid setling, achieving a inal 50% organic mater removal with respect to the raw OMW-3 (COD = 70 g/L). Turano et al [23] proposed centrifugation as pretreatment, simple, and mechanical operation which does not need addition of chemicals and is available in the production line, before UF-polysulfone, molecular weight cutof (MWCO) 17 kDa-for the treatment of OMW-3. The centrifugation pretreatment removed 80% of the suspended solid concentration, and 90% COD reduction was achieved at the outlet of the integrated process.…”
Section: Microiltration and Ultrailtration Membranesmentioning
confidence: 99%
“…They proposed a pretreatment consisting of oil removal and suspended solid setling, achieving a inal 50% organic mater removal with respect to the raw OMW-3 (COD = 70 g/L). Turano et al [23] proposed centrifugation as pretreatment, simple, and mechanical operation which does not need addition of chemicals and is available in the production line, before UF-polysulfone, molecular weight cutof (MWCO) 17 kDa-for the treatment of OMW-3. The centrifugation pretreatment removed 80% of the suspended solid concentration, and 90% COD reduction was achieved at the outlet of the integrated process.…”
Section: Microiltration and Ultrailtration Membranesmentioning
confidence: 99%
“…The UF membrane performance was also improved in terms of the volume feed recovery factor (VFR), achieving up to 88.2 vs. 87.2% and 90.7 vs. 89.3%. Turano et al (2002) reported the use of centrifugation as pretreatment prior to the UF of OMW from a three-phase mill. However, despite the relevant COD reduction, the organic matter concentration in the final permeate stream was still too high.…”
Section: Infl Uence Of the Different Pretreatments On The Threshold Umentioning
confidence: 99%
“…In literature, several treatment options and strategies including; centrifuge [1], evaporation [2], filtration [3], ecoagulation [4]- [5] and applying to land [6] have been proposed for management of olive mill wastewater. Besides these methods; advanced treatment processes such as ozonation [7]- [8]- [9], photocatalysis [10], electrocoagulation [5]- [11], fenton oxidation [12], ozone and fenton oxidation [13] and wet air oxidation [14] have been tested for olive mill wastewater treatment.…”
Section: Introductionmentioning
confidence: 99%