An Inductively Coupled RF System for the Transmission of 1 kW of Power Through the Skin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
26
0

Year Published

1984
1984
2020
2020

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 79 publications
(26 citation statements)
references
References 3 publications
0
26
0
Order By: Relevance
“…This frequency range enabled the development of a smaller, patient-compliant, implant coil (transmitter diameter, 5 cm; implant diameter, 3 cm). Unlike the findings of Schuder et al, 17 heat production is negligible because of the pulsed nature of the energy delivery (each pulse equates to 1 delivered shock).…”
Section: Transcutaneous Rf Energy Transfermentioning
confidence: 66%
See 2 more Smart Citations
“…This frequency range enabled the development of a smaller, patient-compliant, implant coil (transmitter diameter, 5 cm; implant diameter, 3 cm). Unlike the findings of Schuder et al, 17 heat production is negligible because of the pulsed nature of the energy delivery (each pulse equates to 1 delivered shock).…”
Section: Transcutaneous Rf Energy Transfermentioning
confidence: 66%
“…Transfer of energy through the skin uses an external coil system to transmit and a stand-alone (passive) internalized coil system to receive the energy (magnetic pulse field) 17,18 via an inductive link. 18 -20 The PIAD uses an "on-off" pulsed RF power source operating at 7.2 MHz and connected to an RF transformer.…”
Section: Passive Implantable Atrial Defibrillatormentioning
confidence: 99%
See 1 more Smart Citation
“…Magnetic resonance was used in this WPT. Transistor-based astable multivibrator used in 1968 for WPT [16] 1971: With a pair of much larger spiral coil made of Litz wires, John Schuder's team continued their research by transferring 1 kW through the skin of a dog (thickness of 7.5 mm) [17]. It is interesting to note that they have considered the tissue conductivity, inductance and capacitance under an operating frequency of 480 kHz.…”
Section: ) Examples Of Wpt Research Conducted By the Bio-medical Resmentioning
confidence: 99%
“…The portion of the electric energy not transmitted to the internal coil is lost in the internal resistance of the power source or electrical wire. To reduce this power loss and thus increase the transmission power, internal and external TET coils are used in resonant circuits, and TET operates at its resonance frequency [1], [5]. This basic TET concept has high energy transmission capability, but the output voltage changes markedly according to the load resistance [1], [2].…”
Section: Introductionmentioning
confidence: 99%