2020
DOI: 10.1109/jestpe.2019.2919649
|View full text |Cite
|
Sign up to set email alerts
|

An Indirect Approach to Control an Active Capacitor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 27 publications
0
4
0
Order By: Relevance
“…For the sake of comparison, the virtual impedance schemes proposed in [38] and [39], the virtual resistance schemes proposed in [14] and [18] and the voltage ripple mitigator scheme proposed in [15] are utilized instead of the proposed GA, under the same test conditions (summarized in Table 1), and the results are depicted in Figs. 13-15. Based on the results that are shown in these figures, we conclude that the activation of the methods under study results to the immediate mitigation of V 2zf ,1 but this does not lead to the full compensation of V 2bus in the presence of line impedances.…”
Section: Simulation Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…For the sake of comparison, the virtual impedance schemes proposed in [38] and [39], the virtual resistance schemes proposed in [14] and [18] and the voltage ripple mitigator scheme proposed in [15] are utilized instead of the proposed GA, under the same test conditions (summarized in Table 1), and the results are depicted in Figs. 13-15. Based on the results that are shown in these figures, we conclude that the activation of the methods under study results to the immediate mitigation of V 2zf ,1 but this does not lead to the full compensation of V 2bus in the presence of line impedances.…”
Section: Simulation Resultsmentioning
confidence: 99%
“…These requirements make them unsuitable for distributed power ripple compensation in microgrids. So, the APD methods that have been considered in this analysis, are those in [14]- [18], [38], and [39], and the method proposed in this paper.…”
Section: Comparative Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…The proposed control algorithm allows to connect the VIC directly to the DC-BUS in the same way as a passive capacitor; therefore, in this case, plugand-play operation is applicable. Note that this work is a breakthrough for much of the VIC-based research that allows plug-and-play operation, including a significant reduction of DC-BUS ripples to a very low level by an improved control method [103,104], modular realization of the active capacitor [105], and electric vehicle (EV) charger applications [106].…”
Section: Capacitor Dynamic Behavior Imitation Strategy (Infinite Capa...mentioning
confidence: 99%