An in vivo investigative protocol for HDR prostate brachytherapy using urethral and rectal thermoluminescence dosimetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2009
2009
2020
2020

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 35 publications
(18 citation statements)
references
References 10 publications
0
18
0
Order By: Relevance
“…Current methods for in vivo dosimetry are mainly based on the application of thermoluminescence detectors (TLDs) (Toye et al 2009) or semiconductor diodes (Waldhäusl et al 2005). TLDs involve offline process providing the integral dose absorbed during patient treatment and require special procedures in order to achieve good precision of the results.…”
Section: In Vivo Dosimetry In Radiotherapymentioning
confidence: 99%
“…Current methods for in vivo dosimetry are mainly based on the application of thermoluminescence detectors (TLDs) (Toye et al 2009) or semiconductor diodes (Waldhäusl et al 2005). TLDs involve offline process providing the integral dose absorbed during patient treatment and require special procedures in order to achieve good precision of the results.…”
Section: In Vivo Dosimetry In Radiotherapymentioning
confidence: 99%
“…A number of different systems to perform in vivo dosimetry have been developed, including passive integrating thermoluminescent dosimeters (TLDs) and active methods based on diodes, diamond detectors, optical fiber-coupled scintillators and MOSFETs (Fagerstrom et al, 2008;Rustgi, 1998;Toye et al, 2009;Waldhäusl et al, 2005;Zilio et al, 2006). Some of these have already been used to perform in vivo prostate dosimetry by directly placing them in either a needle in the prostate, a catheter in the urethra or in the rectum (Seymour et al, 2011;Suchowerska et al, 2011 .…”
Section: Trus-probe Integratedmentioning
confidence: 99%
“…TLDs have given good results for HDR prostate brachytherapy IVD [8][9][10] but do not allow a real time measurement approach. Haughey et al [11] used a metal-oxide semiconductor field effect transistor (MOSFET) linear array inside the rectum during HDR prostate brachytherapy but concluded that the approach was not suitable due to the difficulties of quantifying uncertainties in MOSFET response.…”
Section: Introductionmentioning