2019
DOI: 10.1038/s41598-018-36805-2
|View full text |Cite
|
Sign up to set email alerts
|

An In-Vitro Study for Early Detection and to Distinguish Breast and Lung Malignancies Using the Pcb Technology Based Nanodosimeter

Abstract: Since the early detection of cancer increases the chance of successful treatment, the present study focused to confirm the suitability of an indigenously fabricated multilayer PCB technology based 3D positive ion detector to detect breast and lung malignancy at an early stage. The 3D positive ion detector is a type of gas filled radiation detector works under the principle of ion induced ionization using an exempted micro curie activity source. Earlier studies report that malignant cells can be detected by ana… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
5
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 34 publications
(15 reference statements)
0
5
0
1
Order By: Relevance
“…It should be noted that variation in the form of tissue samples could affect headspace extraction and consequently the repeatability of the measurements. Additionally, the available tissue samples used 61 , 79 were rather small (~10 mg or 100 mg respectively), which potentially influence the sensitivity of the analytical method employed and thereby the recognition of volatiles in trace concentrations.…”
Section: Discussionmentioning
confidence: 99%
“…It should be noted that variation in the form of tissue samples could affect headspace extraction and consequently the repeatability of the measurements. Additionally, the available tissue samples used 61 , 79 were rather small (~10 mg or 100 mg respectively), which potentially influence the sensitivity of the analytical method employed and thereby the recognition of volatiles in trace concentrations.…”
Section: Discussionmentioning
confidence: 99%
“…De los análisis de COV provenientes de líneas celulares, se identificaron cinco estudios basados en la experimentación in vitro de líneas celulares y biopsia de tejido mamario maligno. En cuatro estudios se empleó la línea celular MCF-7 [16][17][18][19] , en dos estudios utilizaron las células MDA-MB-231 [17][18][19] y en un estudio utilizaron biopsias de tejido mamario maligno 20 . Como resultado, se obtuvieron 72 COV agrupados en su mayoría en alcoholes, cetonas, alcanos y aldehídos (Fig.…”
Section: Evidencia In Vitro De Que Las Líneas Celulares «Exhalan» Covunclassified
“…MID technology has become well-known because of its freedom of geometric design in combination with selective structuring and metallization of 3D layout. It is able to define the angle between components, stacking of chips and foaming of cavities in contrast to the traditional printed circuit boards (PCBs) that are two-dimensional one [ 6 , 7 , 8 , 9 , 10 , 11 ]. Moreover, MIDs not only reduce the number of components and the cost by the embedding parts such as connector within a single device but also may save space and shorten assembly time.…”
Section: Introductionmentioning
confidence: 99%