An In vitro skin corrosivity test—Modifications and validation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0
1

Year Published

1990
1990
2018
2018

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 49 publications
(12 citation statements)
references
References 4 publications
0
11
0
1
Order By: Relevance
“…Measurements of electrical resistance is the primary endpoint, a reduction in the TER below a threshold level (5 kΩ for rat) indicates corrosivity. 11 Detailed guidelines are available at OECD Test Guideline 430; 2013. 9,12 Membrane Barrier Test Method for Skin Corrosion This utilizes an artificial membrane designed to respond to corrosive substances and may be used to test solids, liquids (with the exception of aqueous materials with a pH between 4.5 and 8.5), and emulsions.…”
Section: Transcutaneous Electrical Resistance Test Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Measurements of electrical resistance is the primary endpoint, a reduction in the TER below a threshold level (5 kΩ for rat) indicates corrosivity. 11 Detailed guidelines are available at OECD Test Guideline 430; 2013. 9,12 Membrane Barrier Test Method for Skin Corrosion This utilizes an artificial membrane designed to respond to corrosive substances and may be used to test solids, liquids (with the exception of aqueous materials with a pH between 4.5 and 8.5), and emulsions.…”
Section: Transcutaneous Electrical Resistance Test Methodsmentioning
confidence: 99%
“…5,10,11 The manifestations of the delayed reaction are similar to acute ICD however follow a "crescendo" pattern of reactivity characterized by a transient increase of the clinical signs and symptoms over time. The unspecific and often overlapping clinical findings as well as unusual course of the skin irritant reaction may thus mimic ACD and indicate the performance of a patch test to differentiate one condition from the other.…”
Section: Delayed Acute Irritant Dermatitismentioning
confidence: 96%
See 1 more Smart Citation
“…Another alternative is the use of skin explants from sacrificed animals. The transcutaneous electrical resistance (TER) test uses such explants from rat to distinguish between corrosive and non‐corrosive chemicals (OECD TG 430) . Test materials are applied for up to 24 hours, and loss of stratum corneum integrity and barrier function is measured as a reduction in TER using a Wheatstone bridge.…”
Section: Testing—spanning the Skinmentioning
confidence: 99%
“…Corrosive substances produce an irreversible loss of normal stratum corneum integrity and function. This is measured as a reduction in the inherent transcutaneous electrical resistance (TER) below a corrosive threshold level 93, 94. The TER is a recommended regulatory approved screening test.…”
Section: Alternatives To Skin Corrosivitymentioning
confidence: 99%