2023
DOI: 10.11607/ijp.6819
|View full text |Cite
|
Sign up to set email alerts
|

An In Vitro Analysis of the Physical and Mechanical Behavior of a PEEK Component for an Implant-Supported and Retained Removable Dental Prosthesis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0
1

Year Published

2023
2023
2023
2023

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(12 citation statements)
references
References 16 publications
0
6
0
1
Order By: Relevance
“…Among the attachments analyzed is the Locator with six studies [ 10 , 11 , 13 , 14 , 16 , 23 ], bar/clip with three [ 12 , 15 , 21 ], magnetic [ 17 ] with one, and a new model of o'ring for the ball attachment with four [ 7 , 22 , 26 , 27 ]. The most analyzed cleansing solutions were NaOCl [ 7 , 11 , 12 , 13 , 15 , 16 ], followed by different alkaline solutions with different commercial brands [ 7 , 10 , 11 , 12 , 13 , 15 , 16 ] with more details found in Table 2 .…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Among the attachments analyzed is the Locator with six studies [ 10 , 11 , 13 , 14 , 16 , 23 ], bar/clip with three [ 12 , 15 , 21 ], magnetic [ 17 ] with one, and a new model of o'ring for the ball attachment with four [ 7 , 22 , 26 , 27 ]. The most analyzed cleansing solutions were NaOCl [ 7 , 11 , 12 , 13 , 15 , 16 ], followed by different alkaline solutions with different commercial brands [ 7 , 10 , 11 , 12 , 13 , 15 , 16 ] with more details found in Table 2 .…”
Section: Resultsmentioning
confidence: 99%
“…Two studies evaluated the effect of pH [ 17 , 21 ] on attachments. One study evaluated the simulation of the effect of saliva [ 14 ] and five studies evaluated the effect of aging on attachments [ 17 , 22 , 23 , 26 , 27 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Correlação entre a força de retenção e a alteração dimensional dos diâmetros. A higienização das overdentures é indispensável para longevidade do tratamento reabilitador e apresenta como obstáculo a composição das próteses por diferentes materiais (BONACHELA et al, 2003;VARGHESE et al, 2007;NGUYEN et al, 2010;YOU et al, 2011;RUTKUNAS et al, 2011;WATCHARAPICHAT et al, 2014;DERAFSHI et al, 2015;KÜRKCÜOGLU et al, 2016;ALGRAISI et al, 2018;KHODADADKASHIP et al, 2019;AYYILDIZ et al, 2020;FELIPUCCI et al, 2020;VALENTE et al, 2021). O método mecânico (escovação) é o método mais utilizado pelos pacientes para higienização de próteses totais (DILLS et al, 1988;PARANHOS et al, 2007;PERACINI et al, 2010;ARRUDA et al, 2017).…”
Section: Quadrados Médiosunclassified