2023
DOI: 10.1007/s10853-023-08219-7
|View full text |Cite
|
Sign up to set email alerts
|

An in situ synthesis of polyaniline/reduced graphene oxide nanocomposite flexible thin film on PET for the room temperature detection of trace level ammonia at ppb level

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 69 publications
1
2
0
Order By: Relevance
“…Response values are observed to decrease on either side of this optimal concentration, which has been found that 1 wt% PANI/rGO sensors prepared using a 1 M HCl concentration demonstrate good NH 3 response capabilities, with different sensing response values increasing with increasing NH 3 concentration. 109 The introduction of GO in the PANI/GO system was observed to improve its response values, similar to the enhancement observed in electrical conductivity. The optimal loading of 1 wt% GO resulted in the strongest response value, reaching 31.2 ± 1.8%.…”
Section: Resultssupporting
confidence: 59%
See 1 more Smart Citation
“…Response values are observed to decrease on either side of this optimal concentration, which has been found that 1 wt% PANI/rGO sensors prepared using a 1 M HCl concentration demonstrate good NH 3 response capabilities, with different sensing response values increasing with increasing NH 3 concentration. 109 The introduction of GO in the PANI/GO system was observed to improve its response values, similar to the enhancement observed in electrical conductivity. The optimal loading of 1 wt% GO resulted in the strongest response value, reaching 31.2 ± 1.8%.…”
Section: Resultssupporting
confidence: 59%
“…Response values are observed to decrease on either side of this optimal concentration, which has been found that 1 wt% PANI/rGO sensors prepared using a 1 M HCl concentration demonstrate good NH 3 response capabilities, with different sensing response values increasing with increasing NH 3 concentration. 109 The introduction of GO in the PANI/GO system was observed to improve its response values, The optimal loading of 1 wt% GO resulted in the strongest response value, reaching 31.2 ± 1.8%. 46 Notably, Gr has shown to play a benecial role in C 7 H 8 and C 6 H 6 gases typically similar to NH 3 sensing measurements which achieved a signicantly higher maximum response compared to other nanocomposite samples.…”
Section: Input Selectionmentioning
confidence: 93%
“…The instrumentation used in conjunction with the sensing technique utterly follows our previous articles. 32,33 At first, the device under test (DUT) was mounted inside the sensing chamber having volume of 150 cc. The sensing chamber was made out of stainless steel (SS).…”
Section: Sensing Methodologymentioning
confidence: 99%