2020
DOI: 10.1109/tpel.2019.2915360
|View full text |Cite
|
Sign up to set email alerts
|

An Improved Rotor Speed Observer for Standalone Brushless Doubly-Fed Induction Generator Under Unbalanced and Nonlinear Loads

Abstract: The conventional control methods for brushless doubly-fed induction generator (BDFIG) normally employ mechanical sensors to acquire the information of rotor speed, which brings many disadvantages in the cost, complexity, reliability, and so on. This paper presents an improved rotor speed observer (RSO) for the sensorless operation of standalone BDFIGs, which is based on the power winding (PW) voltage and control winding (CW) current. In order to eliminate the impact of unbalanced and nonlinear loads on the RSO… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 32 publications
(15 citation statements)
references
References 22 publications
(53 reference statements)
0
15
0
Order By: Relevance
“…The two control target settings in this paper are shown in (14) and (20). According to (7), the negative sequence 5th-order and positive sequence 7th-order components in i p and u p are shown as 6th-order harmonics in the fundamental synchronous rotating coordinate system, which will not be changed by the system operating state.…”
Section: A Control Structure Optimizationmentioning
confidence: 99%
See 3 more Smart Citations
“…The two control target settings in this paper are shown in (14) and (20). According to (7), the negative sequence 5th-order and positive sequence 7th-order components in i p and u p are shown as 6th-order harmonics in the fundamental synchronous rotating coordinate system, which will not be changed by the system operating state.…”
Section: A Control Structure Optimizationmentioning
confidence: 99%
“…Control methods for DFIM generation systems working under distorted grids were widely studied in [10]- [13]. A sensorless control method for the standalone BDFM generator with unbalanced and nonlinear loads was applied in [14]. In [10] - [12], as a part of the grid, the capacity of doubly-fed generator is far less than the distorted grid.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“… Machine-Parameter-Free Speed Observers All the closed-loop estimation approaches mentioned above are severely dependent on the machine parameters, which would degrade the system robustness against the machine parameter mismatch. In order to address this issue, some typical machine-parameter-free speed observers have been developed for standalone BDFIG [103]- [105].…”
Section:  Speed Observers Dependent On Machine Parametersmentioning
confidence: 99%