An improved power control strategy for grid‐connected hybrid microgrid without park transformation and phase‐locked loop system

Abstract: Summary Voltage source converters are important elements of grid‐connected microgrid, as these integrate distribution generators of microgrid with utility grid. Often due to lack of efficient and flexible control, these converters do not perform as per expectations. Many control methods based on dq current control theory had been developed for grid‐connected microgrids inverters to control power flow between microgrid and grid. However, all these controllers used phase locked loop systems for grid synchronizat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 40 publications
(9 citation statements)
references
References 47 publications
0
5
0
Order By: Relevance
“…For this, the voltage at the inverter terminals is measured and then transformed via dq transformation to gain the phase angle as well as the PLL frequency used as the reference value for the f/P loop. The same voltage is also transformed via alpha-beta transformation to calculate V abs as the reference value for the V/Q relation, since alpha-beta transformation depicts better stability than dq transformation [25]. Pm and Qm are calculated with the power relation in the alpha-beta domain, following this formula:…”
Section: Modeling Of Grid-supporting Invertermentioning
confidence: 99%
“…For this, the voltage at the inverter terminals is measured and then transformed via dq transformation to gain the phase angle as well as the PLL frequency used as the reference value for the f/P loop. The same voltage is also transformed via alpha-beta transformation to calculate V abs as the reference value for the V/Q relation, since alpha-beta transformation depicts better stability than dq transformation [25]. Pm and Qm are calculated with the power relation in the alpha-beta domain, following this formula:…”
Section: Modeling Of Grid-supporting Invertermentioning
confidence: 99%
“…By using the available modules from RSCAD library for various MG components, the AC MG is modeled and these components mathematical modeling adopted from [26]. The specifications of all the MG components are presented in Appendix Table IA.…”
Section: Testbed Of Ac Microgridmentioning
confidence: 99%
“…To circumvent the PLL system's limitations, some studies [23][24][25] proposed frequency locked loop (FLL)-based synchronization solution for the MG's VSI [23][24][25]. Power control approach based on PLL-less CCT is introduced in [26] for grid-tied hybrid MG's VSI. Although power tracking performance of these control systems have improved marginally, there are still undesired ripples observed in both real and reactive powers.…”
Section: Introductionmentioning
confidence: 99%
“…A small-signal model of the Luenberger observer phase-locked loop is established to collect main research data through real-time operation during the stability analysis and parameter design of the Luenberger observer phase-locked loop. Figure 5 shows the small-signal model of the phase-locked loop of the Luenberger observer designed here [ 23 ].…”
Section: Stability Analysis and Parameter Design Of The Luenberger Ob...mentioning
confidence: 99%